Agreement Between Automated Cephalometric Analysis and Expert-Performed Manual Digital Tracing: A Comparative Study
Radu Mihăilescu, Dorin Ioan Cocoș, Ioana Suciu, Alexandrina Muntean, Manuela Chibelean, Bianca Ioana Todor, Khaled Madani, Mariana Păcurar
Key points
From the paper's conclusion- These findings support clinician verification of diagnostically relevant measurements and caution against assuming interchangeability solely on the basis of high ICC values.
Abstract
Background/Objectives: Automatic cephalometric analysis may reduce processing time in orthodontic practice, but its clinical reliability depends on the agreement of derived measurements with expert assessment. This study aimed to evaluate the agreement between automatic cephalometric analysis and manual digital tracing performed by an orthodontic specialist for continuous cephalometric measurements and sagittal skeletal classification using AudaxCEPH Cephalometric software. Methods: In this retrospective comparative study, 97 lateral cephalometric radiographs were analyzed using manual digital tracing by a specialist in orthodontics and dentofacial orthopaedics and automatic tracing with AudaxCEPH Version 2.0. Skeletal, dental, and soft-tissue parameters derived from the Segner–Hasund and LBD analyses were compared using paired statistical tests and agreement analyses for continuous and categorical outcomes. Sagittal skeletal classification was based on prespecified ANB thresholds (Class III, <0°; Class I, 0–4°; Class II, >4°), applied identically to both tracing approaches, and classification concordance was assessed using Cohen’s κ. Results: Sagittal skeletal classification was concordant in 93 of 97 examinations (95.88%; 95% CI, 89.87–98.38%), with an unweighted Cohen’s κ of 0.927 (95% CI, 0.858–0.997) and a linearly weighted κ of 0.936 (95% CI, 0.876–0.997). Agreement for continuous measurements varied across cephalometric parameters. ANB showed a mean bias of +0.31° (95% limits of agreement [LoA], −1.16° to +1.77°), whereas NL/ML exhibited a mean bias of −0.92° with substantially wider LoA (−5.29° to +3.45°). For NL/ML, 40 of 97 examinations (41.24%) exceeded the exploratory 2° difference threshold. Among parameters without identical exported measurements, ICCs ranged from 0.92 to 0.997; OcP/TVL and −1/OcP yielded identical recorded outputs (ICC = 1.00), although independence of the underlying geometric constructions could not be confirmed. Automatic tracing required approximately 20 s compared with 4–7 min for manual digital tracing. Conclusions: AudaxCEPH automatic tracing substantially reduced initial analysis time and demonstrated high overall concordance with expert-performed manual digital tracing. However, agreement was parameter-dependent, with substantial individual-level disagreement for selected measurements, particularly NL/ML. These findings support clinician verification of diagnostically relevant measurements and caution against assuming interchangeability solely on the basis of high ICC values.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A comparison of semi-automated AI-based WEBCEPH, Dolphin, Quick Ceph softwares and manual technique in lateral cephalometric radiographs tracing of orthodontic adult patientsBMC Oral Health · 2026
- Artificial Intelligence-Assisted Cephalometric Analysis: A Comparative Study Between WebCeph and NemoCeph.International journal of dentistry · 2026
- Class-Stratified, Axis-Resolved Inter-Rater Agreement of Cephalometric Landmark Identification and Six Sagittal Discrepancy Measurements: A Secondary AnalysisApplied Sciences · 2026
- Automatic Cephalometric Landmark Localization on CBCT-Derived Digitally Reconstructed Radiographs for Skeletal Malocclusion Classification.ArXiv · 2026
- Beyond Landmark Error: Agreement Between AI-Assisted and Manual Cephalometric Tracing at the Level of Clinical Measurements: A Systematic Review.Tomography (Ann Arbor, Mich.) · 2026
- Reliability of AI-driven cephalometric analysis on CBCT: comparison with manual 2D cephalometryProgress in Orthodontics · 2026