Comparative evaluation of vertical fracture resistance and retrieval outcomes using ultrasonic, LeoPen loop, and XP-Endo shaper systems: an in vitro study
Mariam Ahmed Mohamed, Nihal Nabil Roshdy, Nermine Hassan
Key points
From the paper's conclusion- Retrieval success was comparable between the combined ultrasonic and LeoPen loop protocol and continuous ultrasonic retrieval, whereas the combined ultrasonic and XP-Endo Shaper retrieval protocol showed a significantly lower retrieval success rate.
Abstract
Background Separated endodontic instruments are a frequent procedural challenge that can compromise treatment outcomes. Retrieval techniques vary in efficiency and may influence root fracture resistance. This study compared the impact of three retrieval systems—ultrasonic tips, LeoPen loop, and XP-Endo Shaper—on vertical fracture resistance (VFR), retrieval time, and retrieval success. Methods Twenty-seven extracted human mandibular molars with moderately curved mesial roots (15–30°) were randomly allocated into three groups ( n = 9): Continuous Ultrasonic Retrieval (Control), Combined Ultrasonic + XP-Endo Shaper Retrieval, and Combined Ultrasonic + LeoPen Loop Retrieval. A 4 mm NiTi fragment was fractured in the middle third of the mesiobuccal canal. Retrieval was performed under magnification, and success (yes/no), retrieval time (min), and post-retrieval VFR (N) were measured using a universal testing machine. Data were analyzed using one-way ANOVA and Fisher’s exact test (α = 0.05). Results The combined ultrasonic and LeoPen loop group achieved a retrieval success of n = 8 (88.9%), which was not significantly different from the ultrasonic control group ( n = 6, 66.7%) ( p > 0.05). However, the XP-Endo Shaper group showed a significantly lower success rate ( n = 1, 11.1%) (Fisher’s Exact test, p = 0.001). Mean ± SD retrieval times were 25.4 ± 8.8 min (LeoPen), 24.0 ± 7.7 min (ultrasonic), and 19.8 ± 5.6 min (XP-Endo Shaper), respectively ( p = 0.11). Mean ± SD VFR values were 711.8 ± 230.1 N (ultrasonic), 730.4 ± 241.0 N (XP-Endo Shaper), and 710.0 ± 215.3 N (LeoPen), showing no significant differences ( p = 0.95). A weak, non-significant correlation existed between retrieval time and VFR (r = − 0.13, p = 0.53). Conclusions All three systems resulted in comparable post-retrieval vertical fracture resistance. Retrieval success was comparable between the combined ultrasonic and LeoPen loop protocol and continuous ultrasonic retrieval, whereas the combined ultrasonic and XP-Endo Shaper retrieval protocol showed a significantly lower retrieval success rate.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of different methods for separated file retrieval from the apical third of curved root canals: In vitro study.Journal of conservative dentistry and endodontics · 2026
- Conservative Custom Wire and Loop-Assisted Retrieval of a Long Separated Instrument Extending Beyond the Apex: A Case Report.Cureus · 2026
- Comparative In Vitro Assessment of Original Reciproc® Blue Instruments vs. Two Replicas: Mechanical Characteristics, Safety, and Efficacy AnalysisOral · 2026
- A Novel Abutment Screw Head Design with an Integrated Retrieval Feature: An In Vitro Study.Dentistry journal · 2026
- Cyclic Fatigue Resistance and Fractured Fragment Length of Three NiTi Rotary Systems: An In Vitro ComparisonOral · 2026
- Efficacy of XP-Endo Finisher R, D-RaCe systems, and H-files in the retrieval of extruded gutta-percha from the periapical space.Dental research journal · 2026