BMC musculoskeletal disorders

Modular 3D-printed axis prosthesis for large C2 bone defect reconstruction based on Chinese population anatomical data: finite element analysis and preliminary clinical outcomes.

Song Gao, Hairui Liu, Chuanlei Ji, Jian Fan, Xiaoyu Zhang, Shi Ding, Ziyang Ma, Guojing Chen,

Department of Orthopaedics, Air Force Medical University Xijing Hospital, Xi'an, 710032, China. · Department of Clinical Oncology, Air Force Medical University Xijing Hospital, Xi'an, 710032, China. yajiel_fmmu@foxmail.com.

Key points

From the paper's conclusion
  • This novel 3D-printed modular prosthesis possesses reliable biomechanical performance, well matches the anatomical morphology of the Chinese population, and serves as a promising alternative for rapid reconstruction after C2 vertebral body tumor resection.

Abstract

BACKGROUND: Reconstruction of large bone defects following C2 vertebral body tumor resection remains a major challenge in upper cervical spine surgery. Conventional reconstruction methods are associated with limitations including a prolonged customization cycle and unsatisfactory anatomical matching. METHODS: Atlantoaxial CT data from 40 healthy subjects were collected for anatomical parameter measurement, followed by the design of a modular prosthesis. A C1-C4 finite element model was established to compare the biomechanical performance between the modular prosthesis and traditional titanium mesh. One patient with C2 vertebral tumor underwent total C2 vertebrectomy and subsequent modular prosthesis implantation. OBJECTIVE: To design a novel modular 3D-printed porous titanium alloy axis prosthesis based on atlantoaxial anatomical data of healthy Chinese individuals, verify its biomechanical safety and stability via finite element analysis, and evaluate its clinical efficacy through preliminary case observation. RESULTS: The prosthesis consists of 9 upper modules and 3 lower modules, allowing patient-specific modular adaptation to the anatomical characteristics of the Chinese population. Finite element analysis revealed reasonable stress distribution and favorable displacement stability. At the 12-month follow-up, the clinical case presented satisfactory prosthesis positioning, and imaging examination indicated obvious bone ingrowth at the prosthesis-bone interface. CONCLUSION: This novel 3D-printed modular prosthesis possesses reliable biomechanical performance, well matches the anatomical morphology of the Chinese population, and serves as a promising alternative for rapid reconstruction after C2 vertebral body tumor resection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.