Early postoperative rotational behavior of a plate-haptic multifocal intraocular lens
Toshiya Yamamoto, Takahiro Hiraoka, Tetsuro Oshika
Key points
From the paper's conclusion- Therefore, this study aimed to evaluate postoperative rotational behavior by examining cases in which a nontoric plate-haptic multifocal intraocular lens (Lentis Comfort.
Abstract
Background Plate-haptic rotationally asymmetric multifocal toric intraocular lenses (IOLs) occasionally exhibit extensive postoperative misalignment. Therefore, this study aimed to evaluate postoperative rotational behavior by examining cases in which a nontoric plate-haptic multifocal intraocular lens (Lentis Comfort. LS-313 MF15, Oculentis GmbH; LC), sharing the same design as the toric model, was implanted intraoperatively in vertical, horizontal, or oblique orientations. Methods Patients who underwent uncomplicated phacoemulsification for age-related cataract with in-the-bag of LC were enrolled. Still images captured from surgical videos at the completion of surgery were superimposed on anterior segment images obtained under mydriasis at 3 or 4 days postoperatively, and the degree of intracapsular LC rotation was measured. Results A total of 202 eyes (202 patients) were included. Postoperative rotation ≥ 20° was observed in 17 eyes (8%), and extensive rotation ≥ 45° occurred in 9 eyes (4%). The intraoperative LC implantation orientation was vertical in 47 eyes (V group), horizontal in 52 eyes (H group), 45° oblique in 52 eyes (45° group), or 135° oblique in 51 eyes (135° group). No significant differences in mean postoperative rotation were observed among the four groups; however, the number of eyes with postoperative rotation ≥ 20° was 0 in the V group, 5 in the H group, 4 in the 45° group, and 8 un the 135° group. Conclusion Although mean postoperative rotation of LC did not differ significantly among implantation orientations, postoperative rotation ≥ 20° was observed when LC was implanted in horizontal or oblique orientations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rotational Stability and Vault Outcomes of the EVO ICL Using Oblique Implanting Orientation Compared to Horizontal/Vertical Implanting OrientationJournal of Refractive Surgery · 2026
- Haptic-Extended Flange Intrascleral Fixation for Single-Piece Acrylic Intraocular Lenses.Journal of clinical medicine · 2026
- Rotational stability and visual outcomes of toric implantable collamer lenses in eyes with horizontal and non-horizontal implanting orientation: an observational study.International ophthalmology · 2026
- Severe Rotisserie Tilt of Scleral-Fixated CT Lucia 602 Intraocular Lenses: A Multicenter Case Series.Ophthalmic surgery, lasers & imaging retina · 2026
- Characteristics of Posterior Corneal Astigmatism in 28,551 Chinese Eyes with Cataracts.Journal of clinical medicine · 2026
- Comparative Two-Year Outcomes of Three Different Three-Piece Intraocular Lenses in Flanged Intrascleral Fixation.Medicina (Kaunas, Lithuania) · 2026