Six-month real-world glycemic improvement after Smart MDI system in type 1 diabetes.
Giada Rossi, Ida Pastore, Laura Montefusco, Lorenzo Pozzi Canova, Francesca D'Addio, Paolo Fiorina
International Center for T1D, Pediatric Clinical Research Center Romeo ed Enrica Invernizzi, DIBIC, Università degli Studi di Milano, 20157 Milan, Italy. · Division of Endocrinology, ASST Fatebenefratelli Sacco, 20157 Milan, Italy.
Key points
From the paper's conclusion- Transition to the Smart MDI system was associated with clinically meaningful improvements in CGM metrics and HbA1c over 6 months. Improvements among individuals not practicing carbohydrate counting suggest that the Smart MDI system may provide standardized decision support also beneficial in less structured self-management settings. Larger studies are warranted to confirm these findings.
Abstract
BACKGROUND AND AIMS: Smart multiple daily injection (Smart MDI) system integrating continuous glucose monitoring (CGM), insulin pens, and decision-support tools may optimize glycemic control in type 1 diabetes (T1D). However, real-world data remain limited. We evaluated 6-month glycemic outcomes following transition to Smart MDI in adults with T1D and explored differences according to carbohydrate counting status. METHODS: This retrospective, single-center, observational study included 24 adults with T1D on MDI who transitioned to Smart MDI. CGM metrics were analyzed at baseline and after 1, 3, and 6 months. The primary outcome was change in time in range (TIR 70-180 mg/dL). Secondary outcomes included time above range (TAR), time below range (TBR), mean glucose, glucose management indicator (GMI), coefficient of variation, and HbA1c. Exploratory analyses compared individuals practicing carbohydrate counting (n = 12) with those who did not (n = 12). RESULTS: TIR increased progressively from 56.1 ± 20.4% to 66.3 ± 17.5% (median change +9.0%, P < .01). TAR and TBR significantly decreased. HbA1c declined from 7.6 ± 1.1% to 7.3 ± 0.9% (median change -0.2%, P = .01). While between-group differences were not significant, individuals not practicing carbohydrate counting showed preliminary within-group improvements in TIR, TAR, mean glucose, GMI, and HbA1c, without increased TBR, whereas changes in the carbohydrate counting group were smaller. CONCLUSIONS: Transition to the Smart MDI system was associated with clinically meaningful improvements in CGM metrics and HbA1c over 6 months. Improvements among individuals not practicing carbohydrate counting suggest that the Smart MDI system may provide standardized decision support also beneficial in less structured self-management settings. Larger studies are warranted to confirm these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Smart MDI System in People With Type 1 Diabetes and High HBA1C: A Randomized Controlled Trial Demonstrating That Response to Alerts Drives Outcomes.Diabetes, obesity & metabolism · 2026
- Prospective multicenter evaluation of glycemic and patient-reported outcomes following transition to a next-generation continuous glucose monitoring system in users of advanced hybrid closed-loop technologyTherapeutic Advances in Endocrinology and Metabolism · 2026
- Continuous Glucose Monitoring in Non-Insulin-Treated Type 2 Diabetes.The New England journal of medicine · 2026
- Improvement in Tight Glycemic Control in Adults with Type 1 Diabetes Using the MiniMed™ 780G Hybrid Closed-Loop System: A Real-World Evaluation.Current diabetes reviews · 2026
- Evaluation of continuous glucose monitoring outcomes and health care resource utilization in patients with non-insulin-treated type 2 diabetes.Journal of managed care & specialty pharmacy · 2026
- Improved glycemic control and lifestyle behaviors with Dexcom continuous glucose monitoring: one-year real-world outcomes from a global registry of people with non-insulin-treated type 2 diabetes in primary care.Diabetes research and clinical practice · 2026