Comparing the outcome of pediatric femoral neck fracture between Ti-Robot surgery and traditional surgery.
Yuan Ma, Hao Yang, Yunfeng Xu, Fangyu Liu, Wenyu Liao, Zhen Bian, Lin Huang, Xieyuan Jiang,
Peking University Fourth School of Clinical Medicine, Peking University, Beijing, China. · Department of Pediatric Orthopedics, Beijing Jishuitan Hospital, Beijing, China.
Key points
From the paper's conclusion- The Ti-Robot system is a feasible adjunctive approach for the treatment of pediatric femoral neck fractures. It improves screw placement accuracy and reduces radiation exposure, although its effect on long-term clinical outcomes requires further investigation.
Abstract
PURPOSE: To evaluate the efficacy of Ti-Robot system (Beijing TINAVI Medical Technology Company, China) compared with conventional surgery. METHODS: We retrospectively analyzed 56 pediatric patients with femoral neck fractures. Patients ranged in age from 3.06 to 16.06 years. Twenty-six patients underwent Ti-Robot-assisted surgery, while thirty patients underwent freehand surgery. Baseline and intraoperative data were collected. During a follow-up period of at least 1 year, fracture healing and functional outcomes were assessed using radiographic evaluation and questionnaires. RESULTS: All patients were successfully fixed with three screws. Baseline characteristics were similar between the two groups. Screw parallelism and femoral neck width coverage were better in the Ti-Robot group. Intraoperative fluoroscopy frequency, radiation dose, drilling frequency, and total screw implantation time were lower in the Ti-Robot group than in the conventional group. There were no significant differences in operative time, intraoperative blood loss, healing time, complication rate, Harris Hip Score, Non-Arthritic Hip Score, or Hip and Groin Outcome Score between the two groups. CONCLUSION: The Ti-Robot system is a feasible adjunctive approach for the treatment of pediatric femoral neck fractures. It improves screw placement accuracy and reduces radiation exposure, although its effect on long-term clinical outcomes requires further investigation. LEVEL OF EVIDENCE: Level III, retrospective cohort study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A retrospective cohort study comparing combined TiRobot navigation and percutaneous minimally invasive FNS fixation versus conventional open reduction FNS for femoral neck fractures.Journal of robotic surgery · 2026
- Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.Journal of robotic surgery · 2026
- Clinical outcomes and learning curve of robot-assisted percutaneous cannulated screw fixation for femoral neck fractures.Frontiers in surgery · 2026
- Early clinical and radiographic outcomes of robot-assisted femoral neck system fixation combined with an additional cannulated compression screw for garden IV femoral neck fractures in young and middle-aged adults: a propensity score-matched retrospective cohort study.Frontiers in surgery · 2026
- TiRobot-assisted cannulated screw fixation for calcaneal fractures: a meta-analysis of surgical trauma, anatomical restoration, and functional recovery.Frontiers in surgery · 2026
- Comparative evaluation of CT-to-Fluoroscopy and Scan-and-Plan registration techniques in robot-assisted pedicle screw placement: a preliminary cadaveric faesibility study.Journal of robotic surgery · 2026