Three-dimensional simulations for planning fenestrated/branched endografts in endovascular aneurysm repair for complex abdominal aortic aneurysm: a retrospective cohort study.
Yujing Zhang, Jing Wang, Chengliang Qu, Dongxu Cai, Li Liu, Xiaodong Li
Department of Cardiovascular Surgery, General Hospital of Ningxia Medical University, Yinchuan, China. · Graduate School, Ningxia Medical University, Yinchuan, China.
Key points
From the paper's conclusion- F/B-EVAR guided by 3D simulation may allow for accurate planning of fenestration and branch positioning, potentially improving procedural success rate and suggesting a potential to enhance the quality of outcomes.
Abstract
BACKGROUND: Endovascular aneurysm repair (EVAR) is used to treat patients with abdominal aortic aneurysm (AAA) who have suitable anatomy, while complex AAAs often require fenestrated and branched stent grafts, necessitating further refinement of the technique. OBJECTIVE: To evaluate the safety and efficacy of fenestrated/branched EVAR (F/B-EVAR) assisted by three-dimensional (3D) printing for treating complex AAA. DESIGN: Retrospective cohort study. METHODS: This multicenter retrospective cohort study collected baseline data and clinical outcomes from patients treated with F/B-EVAR between January 2012 and June 2025. The population was divided into the 3D simulation group and the conventional measurement group. The 3D simulation group underwent a simulation to assess fenestration and branch positioning strategies. Study endpoints included procedural success rate, incidence of periprocedural complications and major adverse events, as well as procedural duration and radiation dose. RESULTS: The mean age of patients was 70.2 ± 8.8 years, with 68.9% being male. Compared to the conventional measurement group, the 3D simulation group had a significantly higher procedural success rate (98.8% vs 91.6%, p < 0.001), shorter procedural duration ((115.2 ± 35.0) min vs (138.7 ± 43.7) min, p < 0.001), and lower radiation dose ((107.2 ± 43.9) mGy vs (144.5 ± 56.3) mGy, p < 0.001). Furthermore, although no significant differences were observed in the incidence of all-cause mortality and major cardiovascular adverse events during the 30-day follow-up between the two groups, the incidence of life-threatening major bleeding, major vascular complications, and acute kidney injury stage ⩾3 was significantly lower in the 3D simulation group. CONCLUSION: F/B-EVAR guided by 3D simulation may allow for accurate planning of fenestration and branch positioning, potentially improving procedural success rate and suggesting a potential to enhance the quality of outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Endovascular aortic repair with the custom-made cook fenestrated device for the treatment of complex abdominal aortic aneurysmsAsian Cardiovascular and Thoracic Annals · 2026
- Patient-specific computational simulation for thoracic endovascular aortic repair in patients with Stanford type B aortic dissection.Frontiers in cardiovascular medicine · 2026
- Patient-specific static and dynamic 3D-printed models for planning endovascular repair of complex aortic disease with physician-modified stent grafts.CVIR endovascular · 2026
- Single Center Experience using Fiber Optic RealShape (FORS) Technology in Patients Treated with Complex Endovascular Aneurysm Repair.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
- Fenestrated-Branched Endovascular versus Open Surgical Repair for Elective Thoracoabdominal Aortic Aneurysms: A Systematic Review and Meta-analysis.European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2026
- Impact of BeFlared Bridging Stent Graft on Fluoroscopy and Procedure Time for Fenestrated Endovascular Aneurysm Repair.Annals of vascular surgery · 2026