From the paper's conclusion- Overall survival estimates at 1 and 4 years were 86.9% and 71.3%, respectively.
Abstract
BackgroundFenestrated endovascular aneurysm repair (FEVAR) has become an essential option for the treatment of complex abdominal aortic aneurysms (AAA). While technological advances and growing operator experience have expanded its applicability, outcomes remain heterogeneous across centers and patient subsets. Evaluating real-world results is crucial to better define the effectiveness, safety, and durability of FEVAR in current practice.MethodsThis is a single-center, retrospective, observational study. Consecutive patients treated with FEVAR for complex AAA with a custom-made Cook device from January 2015 to October 2025 were included. Outcomes accessed included technical success, early major systemic complications, overall survival, freedom from reinterventions, target vessel instability, endoleaks, and sac expansion.ResultsSixty-four consecutive patients were treated with FEVAR Cook, of which 23 (35.9%) for juxtarenal AAA, 35 (54.7%) pararenal AAA and 6 (9.4%) thoraco-abdominal type IV aortic aneurysm. All but three patients were treated electively (95.3%). Two hundred twenty-two target vessels were successfully cannulated and treated with a bridging stent. Technical success was 98.4%. Early major systemic complications rate was 14.1%. Median follow-up was 29.5 months (IQR 47). Overall survival estimates at 1 and 4 years were 86.9% and 71.3%, respectively. Estimates at 4 years of freedom from reinterventions and target vessel instability were 90.9% and 93.8%, respectively. Freedom from type I/Ic and III/IIIc endoleak was 95.3% at 4 years. Sac regression, stability, and expansion at follow-up occurred in 29.5%, 63.9%, and 6.6%, respectively.ConclusionsFEVAR emerges as an appropriate and effective treatment option for complex aortic aneurysms. In our experience, the procedure provides high technical success and durable target-vessel preservation, with very satisfactory outcomes even at mid- to long-term follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long Term Target Vessel Outcomes in Patients Treated with Fenestrated Endovascular Aortic RepairEuropean Journal of Vascular and Endovascular Surgery · 2026
- Geometrical Analysis of Target Vessel Instability After FEVAR With Anaconda Stent-Graft SystemJournal of Endovascular Therapy · 2026
- Outcomes of Inner Branches in Endovascular Repair of Complex Abdominal and Thoracoabdominal Aortic Aneurysms.European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2026
- Repair durability following fenestrated versus chimney endovascular repair for elective juxtarenal abdominal aortic aneurysms: a multicenter cohort study.Annals of vascular surgery · 2026
- Real world one-year outcomes of the GORE® VIABAHN® balloon-expandable endoprosthesis in FEVAR and BEVAR: insights from the EXPAND and EMBRACE registries.The Journal of cardiovascular surgery · 2026