The journal of vascular access

Safety and feasibility of large-bore internal jugular vein access for leadless pacemaker implantation: A systematic review and meta-analysis.

Wiktor K Gmiński, Mrunalini Dandamudi, Darya Chekhava, Athanasios J Stefanis, Juliana M Giorgi

Clinical Department of Cardiology, The Ludwik Rydygier Provincial Polyclinical Hospital, Toruń, Poland. · Montefiore Einstein Medical Center, Bronx, NY, USA.

Meta-analysis

Key points

From the paper's conclusion
  • IJV access appears technically feasible for leadless pacemaker implantation in selected adult and pediatric patients. Evidence is insufficient to determine whether it reduces vascular or overall major complications compared with femoral access. Prospective multicenter studies with standardized outcome definitions, protocolized vascular surveillance, and contemporaneous comparators are required.

Abstract

BACKGROUND: Leadless pacemaker (LP) implantation requires a large-bore (up to 27-French) delivery sheath. The femoral vein is the standard access route; however, it carries the risk of major bleeding and may be precluded by venous occlusion. The internal jugular vein (IJV) provides an alternative trajectory. Consolidated data on its vascular safety and procedural feasibility are lacking. METHODS: We searched PubMed, Scopus, ScienceDirect, and Web of Science through December 2025 for studies evaluating IJV-guided LP implantation. Pooled incidence rates and risk ratios (RR) for comparative cohorts were estimated using a random-effects model. RESULTS: Eleven observational studies were included after outcome-specific removal of overlapping participants. The descriptive IJV cohorts showed high reported procedural success, but definitions and denominators varied across outcomes. In two non-randomized comparative cohorts, no major vascular access-site events were reported in the IJV arms (0/132) and 17 were reported in the femoral arms (17/124). These unadjusted comparisons were at serious-to-critical risk of bias because of historical controls, baseline imbalances, differential ultrasound use, and non-standardized event ascertainment. CONCLUSION: IJV access appears technically feasible for leadless pacemaker implantation in selected adult and pediatric patients. Evidence is insufficient to determine whether it reduces vascular or overall major complications compared with femoral access. Prospective multicenter studies with standardized outcome definitions, protocolized vascular surveillance, and contemporaneous comparators are required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Safety and feasibility of large-bore internal jugular vein access for leadless pacemaker implantation: A systematic review and meta-analysis — Science Skim