Within-session repeatability of femoral nerve shear wave elastography across fixed sequential Thomas test-derived protocol in healthy young adults.
Olga Sánchez-Ramirez, Ángel González-de-la-Flor, Charles Cotteret, Jaime Almazán-Polo
Universidad Europea de Madrid Faculty of Medicine, Health and Sports Department of Physiotherapy, Villaviciosa de Odón, Madrid, Spain. · Department of Nursing, Faculty of Nursing, Physiotherapy and Podiatry, Universidad Complutense de Madrid, Madrid, Spain.
Key points
From the paper's conclusion- Cervical flexion produced no significant additional increase.ConclusionIn healthy young adults, scanner-derived SWE estimates obtained from an ROI positioned over the femoral nerve showed high immediate within-session repeatability across a fixed sequential five-position protocol.
Abstract
BackgroundHip and knee influences on femoral nerve mechanical behavior and SWE repeatability remain underexplored.ObjectiveTo describe scanner-derived SWE estimates from an ROI over the femoral nerve across five sequential Thomas test-derived positions and assess within-session repeatability.MethodsIn a single-session repeated-measures study, 19 healthy young adults underwent SWE in supine, Thomas test-derived, modified Thomas test (mTT) with 45° knee flexion, mTT with 90° knee flexion, and mTT with 90° knee flexion plus active cervical flexion. Shear-wave velocity (SWV; m/s) was the principal outcome. The manufacturer-derived apparent Young's modulus (kPa) was recorded as a secondary descriptive outcome. Three consecutive acquisitions were obtained at each position. Within-session repeatability of the three acquisitions was quantified using ICC, SEM, and MDC95. Repeated-measures ANOVA and Bonferroni-adjusted pairwise comparisons assessed differences across the fixed sequential protocol.ResultsRepeatability of the average of three acquisitions was high (ICC[3], 0.964-0.984; SEM, 0.09-0.10 m/s and 1.59-2.63 kPa; MDC95, 0.25-0.28 m/s and 4.40-7.29 kPa). Estimates differed across sequential positions (SWV: F = 40.20, p < 0.001, ηp2 = 0.691; kPa: F = 36.68, p < 0.001, ηp2=0.671). Mean SWV increased from 2.87 ± 0.66 m/s in supine to 4.80 ± 0.59 m/s in mTT with 90° knee flexion. Cervical flexion produced no significant additional increase.ConclusionIn healthy young adults, scanner-derived SWE estimates obtained from an ROI positioned over the femoral nerve showed high immediate within-session repeatability across a fixed sequential five-position protocol. Across this protocol, the highest apparent stiffness and SWV estimates were observed during the mTT position with 90° of knee flexion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of operator experience and measurement depth on skeletal muscle shear wave elastography.Journal of ultrasound · 2026
- Awareness, Access and Use of Shear Wave Elastography and MyotonPRO Among Physiotherapy Students and Practicing Physiotherapists: A Cross-Sectional Survey.Healthcare (Basel, Switzerland) · 2026
- Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis.Sensors (Basel, Switzerland) · 2026
- Shear-Wave Elastography in Musculoskeletal Pain: Current Evidence and Clinical Applications for Tissue Stiffness Assessment.Medicina (Kaunas, Lithuania) · 2026
- Automatic Reconstruction Algorithms for In Vivo Skeletal Muscle 3D-SWEI Data.IEEE transactions on ultrasonics · 2026
- Muscle activation assessment using ultrasound time-harmonic elastography and tonic vibration reflexJournal of Biomechanics · 2026