Sensors (Basel, Switzerland)

Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis.

You-Ruei Hou, Shiuan Lin, Yan-Ci Liu, Yu-An Chen, Yi-Hsuan Lee, Jiu-Jenq Lin, Szu-Hua Chen, Wei-Li Hsu

School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei 100, Taiwan. · Department of Gerontological Health Care, Yuanpei University of Medical Technology, Hsinchu 300, Taiwan.

Randomised · n=40

Key points

From the paper's conclusion
  • Intermittent local muscle vibration produced smaller immediate knee JPS errors, whereas continuous vibration elicited larger hemodynamic responses.

Abstract

This randomized crossover study compared immediate responses to different local muscle vibration protocols in 40 adults with knee osteoarthritis. Participants were randomized 1:1 to receive intermittent or continuous vibration first, then crossed over to the alternative protocol after washout. Vibration targeted the vastus medialis during 120 s of sit-to-stand exercise. Intermittent vibration was delivered only during seated and standing holds, whereas continuous vibration was delivered throughout the exercise. Knee joint position sense (JPS) errors were assessed at 20°, 40°, and 60° of flexion using inertial measurement units. Near-infrared spectroscopy recorded prefrontal and muscle hemodynamic responses during JPS testing. Assessments were performed at baseline and after each protocol. Data were analyzed using repeated-measures analysis of variance. Intermittent vibration produced smaller JPS errors than continuous vibration at all angles (1.96° versus 2.87°, 2.17° versus 3.20°, and 2.78° versus 4.72°, respectively, all p ≤ 0.019). Intermittent vibration elicited smaller changes in prefrontal total hemoglobin (0.23 versus 0.66 μM, p < 0.001), muscle oxygenated hemoglobin (2.32 versus 5.53 μM, p = 0.003), and muscle total hemoglobin (2.59 versus 6.13 μM, p = 0.004). Intermittent local muscle vibration produced smaller immediate knee JPS errors, whereas continuous vibration elicited larger hemodynamic responses.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Intermittent Local Muscle Vibration Produces Smaller Knee Joint Position Sense Errors than Continuous Vibration: A Randomized Crossover Study in Knee Osteoarthritis — Science Skim