Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

Influence of thread profiles, microthreads, and cutting flutes on dental implant performance: A finite element study.

Ayush Yadav, Suraj Mali, Pankaj Dhatrak, Santosh Patil

Department of Bioengineering, Dr. Vishwanath Karad MIT World Peace University, Pune, Maharashtra, India. · Department of Mechanical Engineering, Dr. Vishwanath Karad MIT World Peace University, Pune, Maharashtra, India.

Key points

From the paper's conclusion
  • This research aims to understand the influence of thread profiles, micro-threading conditions, and cutting flutes using finite element analysis.

Abstract

Dental implant success is highly dependent on implant design parameters such as thread profile, micro-threading, and cutting flutes, bone quality and loading conditions. Enhancing these design parameters is essential to achieve better stress dispersion and ensure stability at the implant bone junction, especially in regions with differing bone densities. This research aims to understand the influence of thread profiles, micro-threading conditions, and cutting flutes using finite element analysis. A total of 24 implant models were designed, incorporating variations in thread geometry and flute configurations, as well as the presence or absence of micro threads. The research focuses on stress distribution in cortical and cancellous bone under a standardized 100 N load at 45° across Type IV bone density. Maximum von Mises stress in cortical bone was observed in the buttress profile with micro-threads and 2 cutting flutes, whereas the non-micro-threaded square profile with 4 cutting flutes exhibited the highest stress in cancellous bone (17.14 MPa). Introducing coronal micro-threads increased peak cortical bone stress by 15%-20% on average while shielding the underlying cancellous bone. Increasing cutting flutes from 2 to 4 contributed to stress reduction primarily in micro-threaded configurations, whereas its effect in non-micro-threaded models was minimal. Within the parameters evaluated, implant design modifications altered simulated stress distribution across cortical and cancellous bone regions in low-density bone. Because specific configurations reduced cancellous stress while increasing peak cortical stress, design selection involves balancing localized cortical stress concentration with stress transmission into the underlying cancellous bone.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers