Influence of thread profiles, microthreads, and cutting flutes on dental implant performance: A finite element study.
Ayush Yadav, Suraj Mali, Pankaj Dhatrak, Santosh Patil
Department of Bioengineering, Dr. Vishwanath Karad MIT World Peace University, Pune, Maharashtra, India. · Department of Mechanical Engineering, Dr. Vishwanath Karad MIT World Peace University, Pune, Maharashtra, India.
Key points
From the paper's conclusion- This research aims to understand the influence of thread profiles, micro-threading conditions, and cutting flutes using finite element analysis.
Abstract
Dental implant success is highly dependent on implant design parameters such as thread profile, micro-threading, and cutting flutes, bone quality and loading conditions. Enhancing these design parameters is essential to achieve better stress dispersion and ensure stability at the implant bone junction, especially in regions with differing bone densities. This research aims to understand the influence of thread profiles, micro-threading conditions, and cutting flutes using finite element analysis. A total of 24 implant models were designed, incorporating variations in thread geometry and flute configurations, as well as the presence or absence of micro threads. The research focuses on stress distribution in cortical and cancellous bone under a standardized 100 N load at 45° across Type IV bone density. Maximum von Mises stress in cortical bone was observed in the buttress profile with micro-threads and 2 cutting flutes, whereas the non-micro-threaded square profile with 4 cutting flutes exhibited the highest stress in cancellous bone (17.14 MPa). Introducing coronal micro-threads increased peak cortical bone stress by 15%-20% on average while shielding the underlying cancellous bone. Increasing cutting flutes from 2 to 4 contributed to stress reduction primarily in micro-threaded configurations, whereas its effect in non-micro-threaded models was minimal. Within the parameters evaluated, implant design modifications altered simulated stress distribution across cortical and cancellous bone regions in low-density bone. Because specific configurations reduced cancellous stress while increasing peak cortical stress, design selection involves balancing localized cortical stress concentration with stress transmission into the underlying cancellous bone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical evaluation of surface texturing and hybrid coatings in dental implants: A finite element analysis of stress distribution under bone loss conditions.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Influence of Implant Macrogeometry on Primary Stability in Different Polyurethane Bone-Density Models: An In Vitro Study.Bioengineering (Basel, Switzerland) · 2026
- The effects of four different thread shapes of dental implants on bone remodeling in D2- and D4 bone types: a finite element investigation.Computer methods in biomechanics and biomedical engineering · 2026
- Influence of Reduced Cortical Bone Compression by Implant Macrogeometry on Peri-Implant Bone Healing: An In Vitro and In Vivo Experimental StudyJournal of Functional Biomaterials · 2026
- Initial biomechanical responses during maxillary first molar intrusion across different root-sinus configurations and sinus floor cortical thicknesses: a three-dimensional finite element study.Odontology · 2026
- Interaction Between Implant Macrogeometry and Osteotomy Preparation on Immediate Mechanical Fixation and Regional Thread Alterations: An Ex Vivo Biomechanical Study.Bioengineering (Basel, Switzerland) · 2026