Six-degree-of-freedom manikin neck for immobilisation training, incorporating linear potentiometers for real-time motion feedback.
Claire F Jones, Mingyue Liu, Margaret Gayen, Liam A Sweet, Ryan D Quarrington, Charlie C Magarey, William S P Robertson
School of Electrical and Mechanical Engineering, Adelaide University, SA, Australia. · Adelaide Medical School, Adelaide University, SA, Australia.
Key points
From the paper's conclusion- The PSM neck prototype demonstrates design elements that enable six-DOF motion, low stiffness and real-time head-neck motion feedback.
Abstract
Neck immobilisation manoeuvres are performed by clinicians when moving patients with suspected cervical spine injuries and may mitigate further harm to the spinal column and spinal cord. Existing patient simulator manikins (PSM) do not have realistic neck articulations and are not instrumented to provide the user with feedback regarding manikin neck motion. The aim of this study was to design, manufacture, and test a proof-of-concept instrumented and articulated neck for an existing PSM. The neck comprised 3D-printed ball-and-socket articulations with 'intervertebral' motion limiting stoppers and extension springs to provide passive neck stiffness. Aluminium adaptor plates and locking mechanisms were designed to interface the neck with existing attachment points without modification of the existing manikin. A passive Stewart-Gough platform arrangement of linear slide potentiometers and a forward kinematics algorithm were used to measure the pose of the head with respect to the torso. Head angle accuracy, range of motion (ROM) and stiffness were assessed. Optoelectronic motion capture in 3D was used for verification measurements. ROM of the neck for flexion (25.0°), extension (29.3°), left (24.7°) and right (21.0°) lateral bending were limited by the potentiometer assembly, while ROM for left (52.5°) and right (48.4°) axial rotation was limited by the stoppers. Neck stiffness remained low until close to the end of ROM (range 5.8-28.3 Nmm/° across all axes) at which point stiffness increased by up to an order of magnitude (43.4-404.5 Nmm/°). Measured head-to-torso angle had root-mean-squared error less than 0.89° compared to motion capture measurements. The PSM neck prototype demonstrates design elements that enable six-DOF motion, low stiffness and real-time head-neck motion feedback. Adjustments to improve ROM, stiffness variation throughout ROM, anatomical realism and evaluation in paramedic training settings, would be required to implement the prototype in immobilisation training.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and implementation of a paradigm-specific cervical manipulation simulator with objective force-angle feedback.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Determination of the Human-Robot Interaction Workspace for Robot Assisted Head Stabilization Control.ArXiv · 2026
- A Decoupled Parallelogram-Flexure Mechanism for Remote Center of Motion in Magnetic Resonance Imaging-Guided Abdominal InterventionsJournal of Mechanical Design · 2026
- Design Improvement of a 5-Bar Linkage-Based Needle Insertion Robot for Pain Intervention ProceduresMachines · 2026
- Physically Constrained Kinematic Calibration for High-Precision Robotic Needle GuidancearXiv · 2026
- The Validity and Reliability of a Novel Testing Device and Six‐Way Neck‐Strength Testing Protocol for Peak Force and Rate of Force DevelopmentEuropean Journal of Sport Science · 2026