Design Improvement of a 5-Bar Linkage-Based Needle Insertion Robot for Pain Intervention Procedures
Jaeho Hyun, Yeongjun Cho, Bomi Yang, Changmo Hwang, Hyun-Jung Kwon, Jaesoon Choi, Youngjin Moon
Key points
From the paper's conclusion- Overall, the redesigned interface reduced structural compliance and improved needle guide stability without altering the fundamental robot architecture.
Abstract
Accurate needle positioning in robot-assisted pain intervention requires kinematic accuracy, structural stiffness, and stable motion transmission under external loading. Our earlier needle insertion robot, based on a spherical five-bar remote-center-of-motion mechanism, exhibited structural deformation and rotational play during repeated bidirectional actuation. This study redesigned the rotational joint while preserving the architecture and degree-of-freedom configuration. Joint geometry was modified to enlarge the supporting contact area by approximately 4.2-fold, and a friction-based keyless shaft coupling was introduced to improve shaft fastening and suppress rotational clearance. An equivalent stiffness model related vertical needle guide loading to structural displacement and rotational joint compliance. Comparative experiments evaluated structural stiffness, rotational lost motion, and phantom insertion stability. The improved design exhibited smaller steady-state displacement under vertical loads of 0.5–2.0 N, reducing displacement to approximately 40–52% of the previous design; linear force–displacement analysis yielded stiffness values of 0.839 and 1.345 N/mm, an approximately 1.60-fold increase. Rotational lost-motion tests showed an increased mean output-to-input peak ratio, indicating improved transmission. Phantom insertion tests, performed under matched insertion-force conditions, showed significantly reduced peak lifting distance for the improved design across all tested insertion angles. Overall, the redesigned interface reduced structural compliance and improved needle guide stability without altering the fundamental robot architecture.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physically Constrained Kinematic Calibration for High-Precision Robotic Needle GuidancearXiv · 2026
- Multi-bevel steerable needles: A mechanics-driven framework for simultaneous optimization of deflection, insertion force, and penetration safety.Journal of the mechanical behavior of biomedical materials · 2026
- Six-degree-of-freedom manikin neck for immobilisation training, incorporating linear potentiometers for real-time motion feedback.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Robot-assisted lumbar facet joint infiltration improves accuracy and reduces radiation exposure compared to the manual technique in a comparative phantom studyScientific Reports · 2026
- Planar Bending of Flexible Instrument Shafts: Modeling and Experimental ValidationCurrent Directions in Biomedical Engineering · 2026
- A Decoupled Parallelogram-Flexure Mechanism for Remote Center of Motion in Magnetic Resonance Imaging-Guided Abdominal InterventionsJournal of Mechanical Design · 2026