The Validity and Reliability of a Novel Testing Device and Six‐Way Neck‐Strength Testing Protocol for Peak Force and Rate of Force Development
Molly Fownes‐Walpole, Cameron Owen, Liam Colbert, Omar Heyward, Kevin Till, Ben Jones
Key points
From the paper's conclusion- This study aimed to (1): evaluate the validity and reliability of a novel strength‐testing device (LINK), and (2) determine the reliability of a practical six‐way (flexion, extension, lateral flexion, rotation) neck‐testing protocol for peak force (PF) and rate of force development (RFD).
Abstract
Neck strength is hypothesised to mitigate head/neck injury and head acceleration events. Studies often only assess maximal isometric neck strength in flexion, extension, and lateral flexion and few consider the criterion and ecological validity of the devices and protocols used. This study aimed to (1): evaluate the validity and reliability of a novel strength‐testing device (LINK), and (2) determine the reliability of a practical six‐way (flexion, extension, lateral flexion, rotation) neck‐testing protocol for peak force (PF) and rate of force development (RFD). LINK validity and reliability were assessed in two parts: (A) criterion validity and inter‐/intra‐LINK reliability for PF against Kistler force platforms; and (B) criterion validity for PF and RFD during an isometric mid‐thigh pull compared with the force platforms. Intra‐tester inter‐session reliability of the neck testing protocol was determined across two sessions. Reliability was assessed using intraclass correlation coefficients (ICC). All LINKs demonstrated excellent intra‐LINK reliability. Two LINKs showed agreement with the force platforms up to 606.8 N (mean bias: 10.6 [2.8–18.4] N and 10.7 [0.6–20.8] N) and excellent inter‐LINK reliability (ICC lower bound > 0.99). One LINK was removed from further analysis due to higher mean bias (23.7 [9.6–37.8] N). The six‐way protocol demonstrated moderate‐to‐excellent reliability for PF (ICC 0.83–0.95; 95% CI between 0.53–0.99), but not for RFD (ICC 0.41–0.94; −0.30 to 0.99). Meaningful detectable changes in neck strength ranged from 38.9 to 58.0 N. This study presents a valid, reliable method for assessing neck PF across six directions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved Hold Time, Unproven Benefit: Reassessing the Cervical Endurance Hold as an Outcome Measure in Fighter Pilots.Military medicine · 2026
- The Reliability and Validity of a Novel Isometric Trunk Rotation Strength Test.International journal of sports physical therapy · 2026
- Between-session reliability and sensitivity of force production characteristics across various force-time points during the isometric single-leg long-lever bridgePLoS ONE · 2026
- Six-degree-of-freedom manikin neck for immobilisation training, incorporating linear potentiometers for real-time motion feedback.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- A Novel Method of Clinical Strength Assessment: Reliability and Validity of a Crane Scale for the Quadriceps and HamstringsThe Journal of Strength and Conditioning Research · 2026
- A Load-Cell-Based Approach to Assess Maximal Anti-Rotation Break Force During the Cable Woodchop: Test-Retest Reliability and Postural Differences.Sensors (Basel, Switzerland) · 2026