Evaluation of wedge-induced photoneutron dose during 15 MV 3D conformal rectal radiotherapy using TLD600/TLD700 pairs.
Tahir Çakır, Hikmettin Demir, Osman Vefa Gül, Nurhak Tatar, Rafet Yılmaz
Department of Biophysics, Van Yuzuncu Yil University, Van, Türkiye. · Department of Radiation Oncology, Van Yuzuncu Yil University, Van, Türkiye.
Key points
From the paper's conclusion- Neutrons have a high radiation weighting factor.PurposeTo compare the thermal neutron sensitive TLD responses with and without wedge use during simulated rectal radiotherapy using TLD600/700 pairs.MethodsTLD pairs were placed in the target (rectal region), bladder, and right femur regions of an anthropomorphic Rando phantom for simulated rectal radiotherapy.
Abstract
BackgroundLinear accelerators are widely used in radiotherapy. However, photoneutron production may occur during high energy photon radiotherapy. Neutrons have a high radiation weighting factor.PurposeTo compare the thermal neutron sensitive TLD responses with and without wedge use during simulated rectal radiotherapy using TLD600/700 pairs.MethodsTLD pairs were placed in the target (rectal region), bladder, and right femur regions of an anthropomorphic Rando phantom for simulated rectal radiotherapy. Computed tomography images were acquired and transferred to the Prowess treatment planning system (TPS). Wedge and non-wedge plans were created using 15 MV photons at a treatment dose of 2 Gy. Plans were delivered using a Siemens Artiste™ linear accelerator. TLDs were read using a Harshaw system, and Am-Be calibrated neutron sensitive responses were expressed in mSv/Gy. Wedge/non-wedge response ratios were also calculated.ResultsAm-Be calibrated values for wedge versus non-wedge plans were 0.37 vs. 0.19 mSv/Gy for the target, 0.43 vs. 0.17 mSv/Gy for the bladder, and 0.51 vs. 0.22 mSv/Gy for the right femur, corresponding to wedge/non-wedge ratios of 1.95, 2.53, and 2.32, respectively.ConclusionsNeutron sensitive TLD responses were higher for the wedge plan than for the non-wedge plan at the same measurement positions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of neutron dose equivalent in prostate stereotactic body radiotherapy by bubble detector.Biomedical physics & engineering express · 2026
- Radiation dose perturbations associated with plastic and metallic tracheostomy tubes: a phantom study.Brazilian journal of otorhinolaryngology · 2026
- External dose characteristics and radiation-protection metrics after permanent 125I prostate brachytherapy: comparison of conventional and sparse implantation techniques.Radiation protection dosimetry · 2026
- Occupational exposure assessment in ROLL procedures with Tc-99m: A Monte Carlo simulation approach.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Angular Distributions of Secondary Neutron and Photon Ambient Dose Equivalent in Proton Therapy: A Systematic PHITS 3.35 Study at 70-250 MeV.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Phantom-Based Study on Testicular Dose Protection Using Different Thicknesses of Low-Melting-Point Lead Shields in Postoperative Radiotherapy for Seminoma.Dose-response : a publication of International Hormesis Society · 2026