Initial Experience with Confocal Laser Scanning Microscopy for Intraoperative Margin Assessment During Robot-Assisted Radical Prostatectomy.
Johnny Wang, Karim Hanna, Michael Dugan, Narmina Khanmammadova, Mohammed Shahait, David I Lee
Department of Urology, University of California, Irvine, Orange, California, USA. · Department of Pathology and Laboratory Medicine, University of California, Irvine, Orange, California, USA.
Key points
From the paper's conclusion- CLM via the HS provides a viable platform for IOMA during RARP. Larger studies are needed to define diagnostic performance and clinical utility.
Abstract
INTRODUCTION: Current approaches to intraoperative margin assessment (IOMA) during robot-assisted radical prostatectomy (RARP) remain limited by time and resource demands. We evaluated the feasibility of confocal laser microscopy (CLM) using the Histolog Scanner (HS) for IOMA during RARP. METHODS: Data was collected from thirteen patients undergoing RARP. Thirty-four margins were scanned using the HS. Primary outcomes were feasibility and workflow integration. Secondary outcomes included concordance of surgeon and pathologist interpretation with final pathology. RESULTS: All scans produced interpretable images without technical failure, device-related adverse events, or interference with standard pathology processing. Mean scan time was 4.17 minutes per margin. Mean review time was 1.47 minutes for the surgeon and 2.69 minutes for the pathologist. Per-margin inter-rater agreement was 93.1%, with an overall accuracy of 86.2%. CONCLUSIONS: CLM via the HS provides a viable platform for IOMA during RARP. Larger studies are needed to define diagnostic performance and clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intraoperative margin assessment using fluorescence confocal microscopy during robot‐assisted radical prostatectomy: a first experienceBritish Journal of Urology · 2026
- Confocal Ex Vivo Margin Assessment in Transoral Laser Cordectomy: A Pilot Diagnostic Accuracy Study.The Laryngoscope · 2026
- IP8-FLUORESCE: A Prospective Paired Cohort Study Evaluating the Diagnostic Accuracy of Fluorescence Confocal Microscopy for Real-time Assessment of Surgical Margins in Radical ProstatectomyEuropean Urology · 2025
- Delphi consensus on ex vivo fluorescence confocal microscopy in robot‐assisted radical prostatectomyBritish Journal of Urology · 2026
- Intraoperative Techniques Aiding Margin Assessment and Nerve Sparing During Robot-Assisted Radical Prostatectomy.Cancers · 2026
- OS13.7.A Confocal laser endomicroscopy outperforms white light and sodium fluorescein for tumour margin assessment in glioma surgery: the Florence experienceNeuro-Oncology · 2026