Confocal Ex Vivo Margin Assessment in Transoral Laser Cordectomy: A Pilot Diagnostic Accuracy Study.
Chiara Alberti, Viscardo Paolo Fabbri, Albino Eccher, Daniele Marchioni, Carlotta Liberale, Samuele Baldelli, Greta Morselli, Raffaella Ciuffreda,
Department of Otorhinolaryngology-Head and Neck Surgery, University Hospital of Modena, Modena, Italy. · Department of Pathological Anatomy, University Hospital of Modena, Modena, Italy.
Key points
From the paper's conclusion- The Histolog Scanner is a feasible, rapid intraoperative screening tool with high specificity and excellent negative predictive value for ruling out involved margins in TLM cordectomy. It serves as an intraoperative adjunct rather than a replacement for definitive histopathology, which remains essential. Larger multicenter studies are required before widespread clinical setting implementation.
Abstract
OBJECTIVES: Margin assessment in transoral laser microsurgery (TLM) for glottic squamous cell carcinoma is challenging due to specimen size, fragmentation, and artifacts. This study evaluated the feasibility and preliminary diagnostic performance of the Histolog Scanner, an ultra-fast ex vivo confocal microscopy system, for intraoperative margin assessment in TLM cordectomy. METHODS: This prospective pilot study evaluated adult patients undergoing TLM cordectomy for glottic squamous cell carcinoma. Five predefined margins per specimen (anterior, posterior, superior, inferior, deep) were evaluated using Histolog Scanner and compared with conventional hematoxylin and eosin histopathology, used as the reference standard. Concordance, sensitivity, specificity, predictive values, and diagnostic accuracy were assessed. RESULTS: Nineteen patients were included, yielding to 95 evaluable margins. Overall concordance between Histolog Scanner and histopathology was 92.6% (88/95 margins). The scanner identified 12 true-positive, 76 true-negative, five false-positive, and two false-negative margins. Sensitivity was 85.7% (95% CI: 57.2-98.2), specificity 93.8% (95% CI: 86.2-98.0), positive predictive value 70.6% (95% CI: 44.0-89.7), negative predictive value 97.4% (95% CI: 91.0-99.7), and accuracy 92.6% (95% CI: 85.4-97.0). Agreement was substantial (Cohen's kappa = 0.73). Mean acquisition time was 13 min per specimen. CONCLUSION: The Histolog Scanner is a feasible, rapid intraoperative screening tool with high specificity and excellent negative predictive value for ruling out involved margins in TLM cordectomy. It serves as an intraoperative adjunct rather than a replacement for definitive histopathology, which remains essential. Larger multicenter studies are required before widespread clinical setting implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Initial Experience with Confocal Laser Scanning Microscopy for Intraoperative Margin Assessment During Robot-Assisted Radical Prostatectomy.Journal of endourology · 2026
- Intraoperative margin assessment using fluorescence confocal microscopy during robot‐assisted radical prostatectomy: a first experienceBritish Journal of Urology · 2026
- Ex Vivo Line-Field Confocal Optical Coherence Tomography and Ex Vivo Fusion Confocal Microscopy for Lateral-Margin Assessment of Basal Cell Carcinoma in Correlation with Histopathology: A Prospective Pilot Diagnostic-Accuracy Study.Cancers · 2026
- IP8-FLUORESCE: A Prospective Paired Cohort Study Evaluating the Diagnostic Accuracy of Fluorescence Confocal Microscopy for Real-time Assessment of Surgical Margins in Radical ProstatectomyEuropean Urology · 2025
- Preliminary results and experiences of fluorescence confocal microscopy using the Histolog® Scanner in prostate cancer diagnostics: a feasibility studyBritish Journal of Urology · 2026
- OS13.7.A Confocal laser endomicroscopy outperforms white light and sodium fluorescein for tumour margin assessment in glioma surgery: the Florence experienceNeuro-Oncology · 2026