First report of daratumumab interference in urine immunofixation electrophoresis confirmed by the HYDRASHIFT 2/4 Daratumumab assay.
Hyun-Woo Lee, Sooho Yu, Se-Eun Koo, Ghee Young Kwon, Kihyun Kim, Hyung-Doo Park
Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. · Department of Pathology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Key points
From the paper's conclusion- Suspecting therapeutic antibody interference, the HYDRASHIFT 2/4 Daratumumab assay (HYDRASHIFT assay) was applied to both serum and concentrated urine samples.
Abstract
A case of analytical interference in urine immunofixation electrophoresis (IFE) caused by daratumumab is presented. Daratumumab, an IgG1-kappa monoclonal antibody, is well-known to produce a false IgG-kappa band in serum IFE, but urinary interference has not been reported because intact IgG is generally not filtered through the glomerulus. A 67-year-old man presented with nephrotic syndrome and was found to have markedly elevated serum creatinine (3.10 mg/dL), free kappa light chains (453.42 mg/dL) and kappa/lambda ratio (23.23). Baseline serum and urine electrophoresis and IFE showed no monoclonal protein (M-protein), while bone marrow examination confirmed light chain deposition disease with kappa restriction. Following two cycles of daratumumab-based chemotherapy, new IgG-kappa bands appeared in both serum and urine IFE despite improving free light chain levels and unremarkable protein electrophoretic patterns. Suspecting therapeutic antibody interference, the HYDRASHIFT 2/4 Daratumumab assay (HYDRASHIFT assay) was applied to both serum and concentrated urine samples. The IgG-kappa bands in both serum and urine IFE disappeared and exhibited a cathodal shift, confirming that they represented daratumumab rather than endogenous M-protein. This case demonstrates that daratumumab may become detectable in urine in the setting of severely impaired glomerular permeability and highlights that the HYDRASHIFT assay can be effectively applied to urine to resolve analytical interference. Awareness of this phenomenon is important for the accurate interpretation of urine IFE results in patients receiving daratumumab.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Resolving Therapeutic Monoclonal Antibody Interference in an Immunoglobulin M Kappa Multiple Myeloma Patient Using a Mass Spectrometry Assay.Clinical laboratory · 2026
- Investigating Denosumab Interference in Serum Protein Electrophoresis.The journal of applied laboratory medicine · 2026
- B-328 MALDI-TOF Mass Spectrometry Demonstrates Superior Analytical Specificity Over Serum Immunofixation for Anti-CD38 Therapeutic BackgroundClinical Chemistry · 2026
- B-137 Diazyme and Freelite Serum Free Light Chain Assays Are Not Clinically Interchangeable at IMWG-Defined Decision PointsClinical Chemistry · 2026
- Absence of Interference on in vitro Clinical Diagnostic Assays Often Performed on Hospitalized Patients by Relmapirazin, a Fluorescent Tracer Agent for Point-of-Care Assessment of Glomerular Filtration Rate.International journal of toxicology · 2026
- Therapeutic monoclonal antibodies mimicking paraproteins in immunofixation electrophoresis: migration profiles of 21 commonly used agents.Clinical chemistry and laboratory medicine · 2026