Left Ventricular End-Diastolic Diameter Predicts Clinical Outcomes in Patients Supported With Surgically Implanted Microaxial Flow Pump.
Ali Fatehi Hassanabad, Yangling Zhao, Joseph G Barile, Yuichiro Kitada, Gabriel Dardik, Justin Fried, Mauer Biscotti, Michael V Genuardi,
Section of Cardiac Surgery, Department of Surgery Columbia University Medical Center, New York Presbyterian Hospital New York NY USA. · Division of Cardiology, Department of Medicine Columbia University Medical Center, New York Presbyterian Hospital New York NY USA.
Key points
From the paper's conclusion- In this real-world, all-comer study, we found that patients with reduced left ventricular dimension who required an Impella 5.5 had worse outcomes. Further research is warranted to recapitulate our observations across more centers.
Abstract
BACKGROUND: This study sought to determine the impact of left ventricular size on clinical outcomes after a microaxial flow pump was surgically implanted. METHODS: In this retrospective cohort study, we included patients who received a surgical microaxial left ventricular assist device from May 2020 to February 2024 at 2 high-volume centers in the United States. Patients were categorized into 2 groups based on their preimplant left ventricular end-diastolic diameter (LVEDD): "small LVEDD," defined as LVEDD ≤5.5 cm, and "large LVEDD," defined as LVEDD >5.5 cm, respectively. End points were all-cause death at 30 days after device implantation, in-hospital death, death 30-days after discharge, and survival at 30-month follow-up. RESULTS: Two-hundred sixty-two patients received an Impella 5.5. Preimplant LVEDD was documented in 194 (74%) patients, where 50 patients had LVEDD ≤5.5 cm and 144 patients had LVEDD >5.5 cm. Patients with a small LVEDD had a higher rate of all-cause death at 30 days after device implantation (32% versus 11.8%, P=0.002), in-hospital death (42% versus 20.1%, P=0.004), and death 30 days after discharge (44% versus 20.8%, P=0.003). In adjusted analyses, patients with a greater LVEDD had 62% decreased risk of long-term death (hazard ratio, 0.39 [95% CI, 0.19-0.76]; P=0.001), compared with patients with a smaller LVEDD. CONCLUSIONS: In this real-world, all-comer study, we found that patients with reduced left ventricular dimension who required an Impella 5.5 had worse outcomes. Further research is warranted to recapitulate our observations across more centers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Natural history of Impella 5.5 in patients with cardiogenic shock and small left ventricular cavities.Frontiers in cardiovascular medicine · 2026
- Utilization of Microaxial Mechanical Circulatory Support Among the Pediatric Population: A Systematic Review.Artificial organs · 2026
- Impact of Partial- to Full-Support Escalation With Microaxial Flow Pumps Prior to Durable Left Ventricular Assist Device ImplantationEuropean Journal of Cardio-Thoracic Surgery · 2026
- Outcomes of microaxial flow pump mechanical circulatory support in cardiogenic shockEuropean Heart Journal · 2026
- A Contemporary Analysis of Microaxial Pump-Associated Cardiac Perforation Events From the FDA MAUDE Database.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Risk Factors and Prediction Models for Early and Long-Term Mortality Following Left Ventricular Assist Device Implantation.Journal of clinical medicine · 2026