Natural history of Impella 5.5 in patients with cardiogenic shock and small left ventricular cavities.
Aarti Desai, Hans Mautong, Peter Wlodkowski, Rebecca Klinbeil, Cetin Alak, Jose Ruiz, Anna Shapiro, Archer Martin,
Division of Heart Failure and Transplantation, Mayo Clinic, Jacksonville, FL, United States. · Internal Medicine Resident, John H. Stroger Jr. Hospital of Cook County, Chicago, IL, United States.
Key points
From the paper's conclusion- These findings strongly support the safety and feasibility of Impella 5.5 in extremely constrained, small LV cavities.
Abstract
The Impella 5.5 is an axillary mechanical circulatory support device used in patients with cardiogenic shock, but those with small left ventricular (LV) cavities may be at risk for suction events, hemolysis, malpositioning, hypoperfusion, and LV injury. Informally accepted guidelines, extrapolated from durable LVAD studies, suggest a minimum left ventricular internal dimension in diastole (LVIDd) of 58 mm, with some clinical practices using a more stringent ≤52 mm cutoff. We retrospectively analyzed 154 consecutive patients supported with Impella 5.5 between January 2020 and December 2024. Overall, 38 patients had an LVIDd ≤58 mm, and 116 had an LVIDd >58 mm; a key subgroup of 21 patients presented with a very small LVIDd of ≤52 mm]. Baseline demographics, comorbidities, body mass index, and renal function were similar [across groups], although those with larger LVIDd had lower ejection fractions (16% vs. 24%, p = 0.001). Median support duration was 24 days in all groups, and pre- and post-implant hemodynamic and laboratory improvements were comparable. Rates of transplantation (79% vs. 90%, p = 0.088) and LVAD implantation (2% vs. 6%, p = 0.159) did not differ significantly in the ≤58 mm cohort. Notably, within the ≤52 mm subgroup, 90-day survival remained high at 90.5% (p = 0.336), with significant improvements in right atrial pressure (17 to 10 mmHg, p = 0.041), mean pulmonary artery pressure (36 to 26 mmHg, p = 0.008), and eGFR (45 to 57 mL/min/1.73m2, p = 0.003). Remarkably, native cardiac recovery was observed exclusively in the smaller LV cohorts, occurring in 11% of the ≤58 mm group (p = 0.003 vs. 0%, p = 0.003) and reaching 19% in the ≤52 mm group (vs. 0% in larger cavities, p < 0.001), while durable LVAD escalation was entirely avoided in the ≤52 mm cohort (0% vs. 6%). Ninety-day event-free survival was excellent across all cohorts 92% vs. 96% in the primary analysis, with no major device-related complications, suction events, clinically significant hemolysis, bleeding, stroke, or escalation to Bi-VAD support. These findings strongly support the safety and feasibility of Impella 5.5 in extremely constrained, small LV cavities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Trajectories of early mobilisation during Impella 5.5 support and associated outcomes in patients with cardiogenic shockEuropean Heart Journal · 2026
- Clinical outcomes of primary Impella 5.5 versus transition from extracorporeal membrane oxygenation in cardiogenic shock: A Spanish multicenter cohort.JTCVS open · 2026
- Biventricular Pressure-Volume Loop Assessment of Impella 5.5 in an Acute ST-Segment-Elevation Myocardial Infarction Shock Model Unmasks Diminished Right Ventricular Reserve.Journal of the American Heart Association · 2026
- Early mobilization trajectories during Impella 5.5 support and associated outcomes in patients with cardiogenic shock: A physiotherapy session-level analysis.Heart & lung : the journal of critical care · 2026
- Repeat Impella 5.5 During Single Hospitalization: A Single Center Experience.Artificial organs · 2026
- Acute Effects of Impella 5.5 on Biventricular Filling and Pressure-Volume Area in Patients With Heart Failure Associated Cardiogenic Shock.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026