Safety and Feasibility of the Lung Volume Reduction Reverser System in Patients with Severe Emphysema: A First-in-Human Pilot Study.
A Susanne Dittrich, Judith Maria Brock, Claus-Peter Heussel, Felix J F Herth, Ralf Eberhardt, Konstantina Kontogianni
Department of Pneumology and Critical Care Medicine, Thoraxklinik at the University Hospital Heidelberg, Heidelberg, Germany. · Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg, Germany.
Key points
From the paper's conclusion- In this severely diseased and small patient cohort, LVR-R implantation was technically feasible. The complication rate was similar to other coil studies and requires a careful pre-procedure benefit-risk evaluation. Two of fourteen bilaterally treated individuals demonstrated a notable improvement in lung function.
Abstract
INTRODUCTION: Endoscopic lung volume reduction with coils is a symptomatic treatment approach for patients with severe pulmonary emphysema and positive collateral ventilation. In this study, we evaluated the safety and feasibility of the new Lung Volume Reduction Reverser (LVR-R) system. METHODS: Prospective, nonrandomized, exploratory, single-center, first-in-man study in 15 patients with chronic obstructive pulmonary disease (COPD) and severe emphysema. Most affected lung lobes were treated sequentially with the LVR-R coils from May 2019 to JUL 2022. Pulmonary function, 6-min walking distance (6-MWD), questionnaires and adverse events were recorded from baseline to 1-year post-procedure. Computer tomography was acquired at baseline and 6 months. RESULTS: A total of 28 procedures were performed, in which 10 (n = 22, 78.6%), 9 (n = 2, 7.1%), or 8 (n = 4, 14.3%) LVR-R coils were implanted, predominantly in the upper lobes (n = 26/28, 92.86%). Two patients refused a second treatment, one of whom refused follow-ups. Adverse events at 3 months included severe pneumonia and/or COPD exacerbations (n = 7), ventilatory failure (n = 2) and 1 pneumothorax requiring thoracic drainage. Mild hemoptysis occurred in 18 and mild pneumonia and/or COPD exacerbations in 9 patients. Overall, neither FEV1, residual volume, 6-MWD, CAT nor mMRC improved within 1-year (n.s. all). In 2 patients, response in FEV1 >500 mL occurred. CONCLUSION: In this severely diseased and small patient cohort, LVR-R implantation was technically feasible. The complication rate was similar to other coil studies and requires a careful pre-procedure benefit-risk evaluation. Two of fourteen bilaterally treated individuals demonstrated a notable improvement in lung function.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of endoscopic lung volume reduction on the rib cage and inspiratory intercostal musclesRespiratory Research · 2026
- EACTS Expert Consensus Document on Lung Volume Reduction for Emphysema.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2026
- The safety and efficacy of lung volume reduction surgery: A 25-year single institution experience.JTCVS open · 2026
- Bronchoscopic and Surgical Interventions for Patients With COPD: A State-of-the-Art Review.Respiratory care · 2026
- Successful Conversion of Collateral Ventilation Status Using the AeriSeal® System Enables Bronchoscopic Lung Volume Reduction with One-Way Valves: CONVERT Trial.Respiration; international review of thoracic diseases · 2026
- Invasive RV pressure-volume loops show hemodynamic benefits of reducing lung hyperinflation in COPD.Respiratory medicine and research · 2026