Compact Size CP Broadband Implantable Antenna Using Rectangular Slots.
Rajiv Kumar Nehra, Ajay Dureja, Vijay Bhuria, Gaurav Yadav, Philemon Yegon
Department of Electronics and Communication Engineering, Bharati Vidyapeeth's College of Engineering (BVCOE), New Delhi, India. · Department of Information Technology, Bharati Vidyapeeth's College of Engineering (BVCOE), New Delhi, India.
Key points
From the paper's conclusion- Because of its favorable combination of small size, circular polarization, bandwidth, and safety performance, the proposed antenna is a feasible choice for implantable biomedical telemetry systems.
Abstract
For biomedical biotelemetry applications, a compact circularly polarized implantable antenna operating in the 2.45 GHz ISM band is proposed. Unlike many recently reported implantable antennas that employ shorting pins, defected ground structures, multilayer configurations, metamaterial loading, or other complex mini-component arrangements to achieve miniaturization and circular polarization, the proposed antenna realizes these functionalities using only strategically etched rectangular slots on a single-layer radiating patch. This straightforward topology maintains ease of manufacture and integration for implantable medical devices while simultaneously achieving significant size reduction, circular polarization, wide impedance bandwidth, and low power-safe operation. The antenna takes up a small space of 5 × 5 × 0.5 mm3, or 0.408 λ0 × 0.408 λ0 × 0.0408 λ0 at 2.45 GHz. Rectangular slots cause the square patch's resonance frequency to drop from 5.74 GHz to 2.45 GHz, which results in a 57.3% reduction in size. The suggested antenna attains a 3 dB axial ratio bandwidth of 7.3% (2.32-2.49 GHz) and an impedance bandwidth of 17.3% (2.25-2.64 GHz). To comprehend the behavior of the antenna and maximize its performance, extensive parametric experiments based on the axial ratio and reflection coefficient are carried out. When normalized to a feasible implant transmit power of -16 dBm, the peak SAR observed under 1 W excitation is 985.9 W/kg; this is well below recognized safety limits, at 0.0247 W/kg. For experimental validation, the implant environment is replicated using minced pork tissue, and the simulated and measured reflection coefficients accord well. Because of its favorable combination of small size, circular polarization, bandwidth, and safety performance, the proposed antenna is a feasible choice for implantable biomedical telemetry systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Compact dual-band implantable antenna for biomedical telemetry with T – shaped and circular patch resonators featuring capacitive ground loadingResults in Engineering · 2026
- A Compact Circularly Polarized Antenna for Wireless Medical ApplicationsMicrowave and Optical Technology Letters · 2026
- An ultra-miniaturized dual-band circularly polarized implantable antenna for neuromuscular prosthetic interfaces.Biomedizinische Technik. Biomedical engineering · 2026
- A highly isolated compact dual-port implantable antenna for biomedical implant applicationsPhysica Scripta · 2026
- A Detuning-Resilient Wideband Microstrip Antenna for Wearable Biomedical Telemetry Through Progressive Interdigital Slot Integration and Patch Defect Engineering.Sensors (Basel, Switzerland) · 2026
- Advances in Miniaturized Implantable Antennas for Biomedical Telemetry: A Review and Comparative AnalysisElectronics · 2026