Office‐to‐education adaptive reuse changes occupancy density, schedules, and activities without necessarily involving a redesign of the existing ventilation system. Evidence on within‐room indoor air quality and occupant perception in converted higher education buildings remains limited. This study examined a mechanically ventilated design studio at Istanbul Gelisim University through measurements in window‐side (Z1), central (Z2), and circulation (Z3) zones and a questionnaire completed by 48 users. Carbon dioxide (CO 2 ), particulate matter (PM 2.5 and PM 10 ), total volatile organic compounds (TVOCs), and grille‐level air velocity were assessed. Mean CO 2 was highest and most variable in Z2 (527 ± 114 ppm; 95th percentile = 760 ppm; maximum = 882 ppm), whereas upper‐end particulate indicators were greater in Z3. Grille velocities showed point‐level heterogeneity despite broadly similar zonal means. Exploratory point‐level comparisons did not establish statistically significant zonal differences in CO 2 , particulate indicators, or TVOC after multiplicity adjustment. Perceived air freshness was positively associated with overall environmental satisfaction (Spearman ρ = 0.475, 95% bootstrap CI 0.219–0.682; Holm‐adjusted permutation p = 0.0022). Respondents could not be linked to individual measurement times and locations, so this association does not establish an exposure–perception relationship. This single case illustrates the value and limitations of combining zone‐based monitoring with occupant assessment in a converted educational space. Sequential monitoring, sensor limitations, and the small number of spatial sampling points restrict inference. The findings support further investigation of supply air distribution and occupant experience rather than a definitive ranking of zones or proof of ventilation inadequacy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Indoor air quality in interior architecture studios: Integrating environmental measurements and occupant perceptionsE3S Web of Conferences · 2026
- Desk‐Level CO 2 Sensing for Monitoring Occupancy and Indoor Environmental QualityIndoor Air · 2026
- Ventilation Performance Under Passive Occupancy Conditions: Impacts on IAQ and Cognitive Function in Lecture HallsIndoor Air · 2026
- Spatial Evaluation of CO 2 Concentration and Relative Humidity in a Glass-Facade Academic Building within a Humid Tropical ClimateBIO Web of Conferences · 2026
- Assessment of personal exposure and spatial concentration variability in a small-scale chemical laboratory.Annals of work exposures and health · 2026
- Β eyond Relaxation: What CO 2 Levels Reveal About Indoor Air Quality in Greek SPA Facilities During COVID‐19?Indoor Air · 2026