Spatial Evaluation of CO 2 Concentration and Relative Humidity in a Glass-Facade Academic Building within a Humid Tropical Climate
Ikrima Said Sabri, Ahmad Zaki, Nursetiawan
Key points
From the paper's conclusion- This study evaluates the spatial distribution of carbon dioxide (CO2) concentration and relative humidity (RH) in a glass-façade academic building and identifies potential mitigation strategies for sustainable building design.
Abstract
The widespread use of glass façades in high-rise academic buildings located in humid tropical climates presents challenges for Indoor Environmental Quality (IEQ), particularly in maintaining adequate indoor air quality and controlling moisture levels. This study evaluates the spatial distribution of carbon dioxide (CO2) concentration and relative humidity (RH) in a glass-façade academic building and identifies potential mitigation strategies for sustainable building design. The research was conducted in the eight-story building, was selected because it represents a typical high-rise academic building with extensive single-glazed façade coverage in a humid tropical climate, making it suitable for investigating indoor environmental performance under real operational conditions. Characterized by extensive single-glazed façade coverage. Field measurements were carried out in December 2025 on Floors 3-8 using Non-Dispersive Infrared (NDIR) sensors for CO2 monitoring and digital thermo-hygrometers for RH assessment. A perimeter-core zoning framework with six measurement points per floor was employed to capture spatial variations, while the Inverse Distance Weighted (IDW) interpolation method was used for spatial visualization. Results showed that average CO2 concentrations ranged from 443.94 to 550.83 ppm, remaining below the Indonesian standard limit of 1,000 ppm and indicating acceptable indoor air quality. However, localized CO2 accumulation was detected in several core zones with limited ventilation. Relative humidity ranged from 60.17% to 71.33%, with the highest values exceeding the recommended comfort range of 55%—65%. The findings highlight the importance of spatial monitoring in identifying localized environmental issues and provide a basis for improving ventilation design and moisture management in glass-façade buildings located in tropical regions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Indoor Air Quality and Occupant Perception in an Office Building Adapted for Educational Use: A Zone‐Based Case StudyIndoor Air · 2026
- Climate-responsive envelope design for educational buildings: A comparative simulation study between the UK and EgyptEnergy and Buildings · 2026
- Indoor Air Quality Performance of Green Versus Conventional Office Buildings: A Systematic Review With Emphasis on Tropical ClimatesEnvironmental Quality Management · 2026
- Development of an evidence-based methodological framework for overheating risk assessment of higher education buildings: occupant-centric retrofitting design strategiesEnergy and Buildings · 2025
- Impacts of air conditioner operation behavior on indoor CO2 concentration and indoor air quality in high-rise apartment: case study in HanoiIOP Conference Series: Earth and Environmental Science · 2026
- Desk‐Level CO 2 Sensing for Monitoring Occupancy and Indoor Environmental QualityIndoor Air · 2026