Novel Configurations of Eccentric and Concentric Helical Coil Heat Exchangers With TCT Insert
A. M. Alklaibi, Iskander Tlili
Key points
From the paper's conclusion- The results show that the stronger helical effect in the concentric arrangement increases the Nusselt number by 20% and the friction factor by 13% compared to the eccentric configuration.
Abstract
This study provides a broader comparative analysis between eccentric and concentric helical heat exchangers. Eccentric tube‐in‐tube helically coiled heat exchangers have received significantly less scholarly attention than their concentric helical counterparts. The primary novelty of this study is the combined implementation of eccentric helical annuli with thin conductive tube (TCT) insert on the annulus side. To this end, configurations combining concentric and eccentric helical heat exchangers—both with and without a TCT insert—are examined across different angular positions. In eccentric configurations, the small tube is displaced toward the inner wall of the outer tube, aligning the centers of the two tubes on a horizontal or vertical line. Three‐dimensional CFD models with fully coupled conjugate heat transfer were developed for all configurations. The eccentric and concentric helical heat exchangers were simulated and solved in ANSYS Fluent across a Reynolds number range of 4313 to 12,939. The working fluids are air and water, with respective inlet temperatures of 600 and 300 K. Validation was performed by comparing the results with established correlations. The results show that the stronger helical effect in the concentric arrangement increases the Nusselt number by 20% and the friction factor by 13% compared to the eccentric configuration. With a TCT insert, the Nusselt number (Nu) of the concentric helical heat exchanger in its horizontal arrangement is 13% higher but the friction factor is 58% higher than that of the eccentric configuration. This is largely due to the rectangular fin that is used in a concentric configuration to conduct heat from the TCT insert to the inner tube. The vertical eccentric configuration is 11% more effective than the standard concentric configuration ( Hcx ) at Re = 12,939. Both configurations benefit markedly from the integration of the TCT insert, but the concentric arrangement yields an ~40% greater improvement compared to the same configuration without the insert. At low Re, a vertical eccentric configuration is recommended to achieve a higher performance evaluation criterion (PEC). Conversely, without a TCT insert, the standard concentric setup is optimal, yielding a higher PEC than the eccentric arrangement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermohydraulic behavior of the triple helical tube with corrugated tube configurationsDiscover Applied Sciences · 2026
- Heat Transfer Enhancement in a Concentric Tube Heat Exchanger Using Dual‐Side Helical Wire Coil Inserts: A Numerical Study With Experimental ValidationHeat Transfer · 2026
- Fluid and thermal flow in annular side of the double twisted helically coiled tubes heat exchangers under various configurationsInternational Journal of Air-Conditioning and Refrigeration · 2025
- Comparative study of fluid flow and heat transfer in corrugated curved tube-in-tube heat exchangers at various configurations using Al2O3/water nanofluidsDiscover Applied Sciences · 2026
- Improving the Thermofluid Performance of a Shell and Corrugated Coil Heat Exchanger With Novel ConfigurationsJournal of Thermal Science and Engineering Applications · 2026
- Nusselt Number Correlations Determined Concurrently on the Hot and Cold Fluid Sides in a Helically Coiled Tube-in-Tube Heat ExchangerEnergies · 2026