Improving the Thermofluid Performance of a Shell and Corrugated Coil Heat Exchanger With Novel Configurations
Mahmoud M. Abdelmagied
Helwan University
Key points
From the paper's conclusion- Abstract In the current investigation, novel coil configurations of a shell and corrugated coil heat exchanger (SCCHX) were experimentally examined and compared with the conventional shell and smooth coil heat exchanger (SSCHX).
Abstract
Abstract In the current investigation, novel coil configurations of a shell and corrugated coil heat exchanger (SCCHX) were experimentally examined and compared with the conventional shell and smooth coil heat exchanger (SSCHX). The innovative coil design enhances the disruption of the thermal boundary layer by increasing the fluid mixing by the curved coil and the corrugation compared to conventional helical designs. This geometry promotes better fluid mixing near the coil surface, resulting in a more uniform temperature distribution, reduced temperature polarization, and a higher temperature difference between the coil and the surrounding fluid. The influence of coil configuration, inclination angle, and Reynolds number on the thermofluid performance was examined. Six curved coils were designed and fabricated for this investigation. Three smooth configurations—model A (divergent–convergent design), model B (convergent–divergent design), and model C (traditional helical design) as well as three corrugated configurations were tested. The experiments were conducted at inclination angles of 0 deg, 45 deg, and 90 deg. The experimental runs covered a range of Dean number of 2000 ≤ Dni ≤ 12,400, corresponding to mass flow rates of 0.032 ≤ ṁi ≤ 0.18 kg/s on the coil side and 0.067 ≤ ṁsh ≤ 0.175 kg/s on the shell side. The new coil configurations showed significant enhancements in the Nusselt number (Nui) by 67.8% and 34.2% for the smooth configurations (models A and B) compared with model C, and by 65.7% and 30.2% for the corrugated configurations at an inclination angle of 90 deg. Conversely, the new coil configurations increased the friction factor (fi) by 26.7% and 50.4% for the smooth configurations (models A and B) compared with model C, and by 21.4% and 31.1% for the corrugated configurations at 90 deg. In addition, the inclination angle of 90 deg recorded the highest thermal performance among all inclination angles, albeit at the expense of higher pressure drop. The maximum thermal performance index (TPI), values of 2.75, 2.6, and 2.5 were obtained for models A, B, and C, respectively, at an inclination angle of 90 deg.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Heat Transfer Enhancement in a Concentric Tube Heat Exchanger Using Dual‐Side Helical Wire Coil Inserts: A Numerical Study With Experimental ValidationHeat Transfer · 2026
- Achieving optimal thermohydraulic efficiency: Comparative study of Semi-Cylindrical and Semi-Conical Coil geometries for heat exchanger designCase Studies in Thermal Engineering · 2026
- Thermohydraulic behavior of the triple helical tube with corrugated tube configurationsDiscover Applied Sciences · 2026
- Enhanced design of a conical coil heat exchanger: A comprehensive analysis of conical angle and fluid flow arrangementsCase Studies in Thermal Engineering · 2026
- Fluid and thermal flow in annular side of the double twisted helically coiled tubes heat exchangers under various configurationsInternational Journal of Air-Conditioning and Refrigeration · 2025
- Comparative study of fluid flow and heat transfer in corrugated curved tube-in-tube heat exchangers at various configurations using Al2O3/water nanofluidsDiscover Applied Sciences · 2026