Heat Transfer Enhancement in a Concentric Tube Heat Exchanger Using Dual‐Side Helical Wire Coil Inserts: A Numerical Study With Experimental Validation
Sanjay Kadam, Abhijeet N. Kore, Rajvardhan Mane, Prashant Gunjavate, Sachin Sawant
Key points
From the paper's conclusion- The results demonstrate that dual‐side wire coil enhancement provides significant thermal performance improvement and can be adopted as a practical retrofit solution for industrial heat exchangers requiring increased heat recovery, reduced equipment size, and improved energy efficiency without major structural modification.
Abstract
Heat exchangers are extensively used in chemical processing, power generation, food processing, HVAC systems, and energy recovery applications, where improving thermal performance without major equipment modification is highly desirable. This study investigates the use of helical wire coil inserts as a passive enhancement technique for improving the performance of a concentric tube heat exchanger operating under turbulent flow conditions. Three configurations were analyzed: a smooth heat exchanger, a heat exchanger fitted with an inner‐tube coil, and a dual‐enhanced configuration incorporating helical wire coils on both the tube side and annulus side. The coil geometries were obtained by scaling the optimum dimensionless ratios ( e / D = 0.036 and p / D = 0.86) reported in previous single‐tube investigations, resulting in a 0.5 mm wire diameter with 12 mm pitch for the 14 mm inner tube and a 1.0 mm wire diameter with 24 mm pitch for the annulus. A three‐dimensional CFD model was developed and validated against experimental data obtained from the smooth heat exchanger, with outlet temperature deviations below 0.1%. Simulations were performed at Reynolds numbers of approximately 5000, 5500, and 6000. The inner‐tube coil increased the hot‐side Nusselt number by 31%–32% and heat exchanger effectiveness by 26%–27% compared with the smooth configuration. When an additional annulus‐side coil was introduced, the hot‐side and cold‐side Nusselt numbers increased by 40%–41% and 41%–43%, respectively, while effectiveness improved by 33%–34%. The annulus‐side thermo‐hydraulic performance factor remained above unity (1.19–1.65), indicating a favorable balance between heat transfer (HT) enhancement and pressure drop penalty. The results demonstrate that dual‐side wire coil enhancement provides significant thermal performance improvement and can be adopted as a practical retrofit solution for industrial heat exchangers requiring increased heat recovery, reduced equipment size, and improved energy efficiency without major structural modification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A novel integrated approach to heat transfer enhancement using baffles and inner fins in helical coil heat exchangersCase Studies in Thermal Engineering · 2025
- Novel Configurations of Eccentric and Concentric Helical Coil Heat Exchangers With TCT InsertInternational Journal of Energy Research · 2026
- Fluid and thermal flow in annular side of the double twisted helically coiled tubes heat exchangers under various configurationsInternational Journal of Air-Conditioning and Refrigeration · 2025
- Improving the Thermofluid Performance of a Shell and Corrugated Coil Heat Exchanger With Novel ConfigurationsJournal of Thermal Science and Engineering Applications · 2026
- Experimental thermal–hydraulic evaluation and correlation development of geometrically modified wire-matrix turbulators in the tube side of double-pipe heat exchangersCase Studies in Thermal Engineering · 2026
- Comparative heat transfer analysis of helical coil and straight tube heat exchangersCase Studies in Thermal Engineering · 2025