Calibration Analysis of BI-RADS: A Patient-centered Approach to the Last Imaging Workup Examination.
Ben A McKinley, Behrang Amini, Gary J Whitman
Weiss School of Natural Sciences, Rice University, Houston, Tex. · Department of Musculoskeletal Imaging, The University of Texas, MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX 77030.
Key points
From the paper's conclusion- Overall, BI-RADS was well calibrated according to CL (0.0031 [95% highest density interval {HDI}: 0.0024, 0.0039]), CIL (0 [95% HDI: 0, 0.0023]), and CS (0 [95% HDI: -0.0023, 0.0019]).
Abstract
Purpose To assess the calibration of the Breast Imaging Reporting and Data System (BI-RADS) for treatment-naive women undergoing routine screening mammography. Materials and Methods This was a retrospective study at a tertiary cancer center of treatment-naive women who underwent screening mammography from 2019 to 2021 with at least 3 years of follow-up. BI-RADS category at completion of imaging workup was compared with presence of cancer as determined by 3 years of follow-up or biopsy. Calibration loss (CL), calibration-in-the-large (CIL), and confidence score (CS) were compared with perfect scores using regions of practical equivalence. True-positive rates for BI-RADS categories were compared with expected values using one-sample proportion hypothesis tests. Subgroup analysis was performed based on age, availability of comparison studies, and breast density. Results Among the 14 964 participants, 232 had cancer (prevalence of 1.6%), average age was 58 years ± 10.5 [SD], and 8579 (57.3%) had dense breasts. Overall, BI-RADS was well calibrated according to CL (0.0031 [95% highest density interval {HDI}: 0.0024, 0.0039]), CIL (0 [95% HDI: 0, 0.0023]), and CS (0 [95% HDI: -0.0023, 0.0019]). Category 1 and 2 predictions had a 1.0% observed rate of cancer, which differed from the expected value of 0%. Category 4 predictions fell within the expected range but were clustered at the lower end of subcategory 4b. CIL differed according to age, whereas CL, CIL, and CS differed according to availability of comparison studies. Breast density did not affect performance. Conclusion Overall, BI-RADS was well calibrated; however, cancer risk was underestimated for categories 1 and 2, and category 4 predictions were heterogeneously distributed. Keywords: Breast, Mammography, Ultrasound, Confidence Calibration, BI-RADS, Breast Cancer © RSNA, 2026.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance of clinical breast cancer risk prediction models vs a mammography-based artificial intelligence risk modelJNCI Journal of the National Cancer Institute · 2026
- Mammographic breast density and arterial calcification as predictors of incident cardiovascular eventsEuropean Heart Journal · 2026
- External validation of four breast cancer risk prediction models for personalized screening in a prospective Dutch screening cohort.NPJ breast cancer · 2026
- Mammography-Based Radiomics for Prediction of Nodal Status and Disease Burden in Breast Cancer: A Temporally Validated Study.Cancers · 2026
- The importance of incidental coronary artery calcification seen on breast radiation therapy planning scans in women after 60 years oldEuropean Heart Journal · 2026
- Development and internal validation of an interpretable mammography-based model for malignancy risk stratification in BI-RADS 4 breast lesions.Frontiers in oncology · 2026