Development and internal validation of an interpretable mammography-based model for malignancy risk stratification in BI-RADS 4 breast lesions.
Yanheng Zhang, Nan Ding, Tingting Jiao, Bin Wang
Linfen People's Hospital, Linfen, China.
Key points
From the paper's conclusion- We developed and internally validated an interpretable mammography-based model for risk stratification within this diagnostic category.
Abstract
BACKGROUND: BI-RADS category 4 breast lesions are suspicious and generally undergo tissue diagnosis, but malignancy risk remains heterogeneous across BI-RADS 4A, 4B, and 4C. We developed and internally validated an interpretable mammography-based model for risk stratification within this diagnostic category. METHODS: This single-center retrospective diagnostic prediction study included 441 patients, each contributing one index BI-RADS 4 mammographic lesion. Outcomes were verified histopathologically in 397 lesions and by longitudinal imaging stability in 44. Three primary models and a sensitivity model excluding BI-RADS were evaluated. Internal validation used 1,000 paired patient-level bootstrap resamples in which imputation, encoding, standardization, penalty selection, LASSO selection, and coefficient estimation were repeated. RESULTS: Of 441 lesions, 165 were malignant. Malignancy rates were 15.7% (34/216), 46.4% (70/151), and 82.4% (61/74) in BI-RADS 4A, 4B, and 4C, respectively. The final model retained BI-RADS 4B, BI-RADS 4C, architectural distortion, circularity-deficit irregularity score, contour serration score, and normalized GLCM contrast. Optimism-corrected AUCs were 0.770 (95% CI, 0.729-0.815) for BI-RADS only, 0.774 (0.733-0.814) for clinical plus BI-RADS, and 0.841 (0.809-0.877) for the full mammography-based model. Clinical variables did not improve validated performance. The full model improved corrected AUC versus BI-RADS only by 0.072 (0.028-0.108) and versus clinical plus BI-RADS by 0.067 (0.029-0.103). Its corrected calibration intercept was 0.002 (-0.209 to 0.208) and slope was 1.445 (1.140-1.753). Within-category AUCs were 0.785, 0.721, and 0.758 for BI-RADS 4A, 4B, and 4C; the pathology-only corrected AUC was 0.835 (0.799-0.871). CONCLUSION: Structured and quantitative mammographic features improved internally validated discrimination and within-category risk stratification beyond BI-RADS subcategory alone. Because predicted risks were under-dispersed and validation was limited to one center, the model should be used only as a research-stage risk-stratification and prioritization tool, not to replace biopsy. External validation and recalibration are required before clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simultaneous Preoperative Prediction of Locally Advanced Breast Cancer, DCIS Component, and Multifocality Using Structured Mammographic Features and Gradient-Boosting Machine Learning.Diagnostics (Basel, Switzerland) · 2026
- Re-stratification of BI-RADS 3/4A breast lesions based on dynamic contrast-enhanced MRI: integrating cardiometabolic risk and breast microvascular remodeling phenotypes to improve diagnostic accuracy and reduce unnecessary biopsies.Frontiers in physiology · 2026
- Mammography-Based Radiomics for Prediction of Nodal Status and Disease Burden in Breast Cancer: A Temporally Validated Study.Cancers · 2026
- Performance of clinical breast cancer risk prediction models vs a mammography-based artificial intelligence risk modelJNCI Journal of the National Cancer Institute · 2026
- Incremental Diagnostic Value of Serum Tumor Markers Beyond Multimodal Ultrasound for BI-RADS Category 4 Breast Lesions: A Retrospective Diagnostic Modeling Study.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
- Diagnostic Performance and Concordance of a BI-RADS-Output AI System in Mammography: A Retrospective Study of Radiologists-AI Collaboration.Journal of imaging informatics in medicine · 2026