Performance of clinical breast cancer risk prediction models vs a mammography-based artificial intelligence risk model
M. Kaul, C. Scott, Alena Wadzinske, Imon Banerjee, Dan Hursh, Aaron Norman, Fang-Fang Wu, Ramon Correa Medero,
Mayo Clinic in Florida · Washington University in St. Louis
Key points
From the paper's conclusion- This study compared model performance of 3 clinical breast cancer risk models: Gail, Tyrer-Cuzick v8, and Breast Cancer Surveillance Consortium v3 with the MIRAI AI-risk model.
Abstract
BACKGROUND: Artificial intelligence (AI)-based, mammography breast cancer risk prediction models show improved discriminatory accuracy relative to clinical risk models. However, data on their calibration are limited. This study compared model performance of 3 clinical breast cancer risk models: Gail, Tyrer-Cuzick v8, and Breast Cancer Surveillance Consortium v3 with the MIRAI AI-risk model. METHODS: Digital mammograms were ascertained from a screening mammography cohort of 12 308 women within the Mayo Clinic Biobank with 250 incident breast cancers (176 invasive) within 5 years. We predicted 5-year breast cancer risk, estimated discriminatory accuracy (C-index), and calibration (observed-to-expected ratio) of both overall and invasive breast cancer and compared estimates using bootstrapping approaches. RESULTS: MIRAI demonstrated similar or improved discriminatory accuracy of overall breast cancer (C-index = 0.71, 95% confidence interval [CI] = 0.68 to 0.74) and invasive breast cancer (C-index = 0.71, 95% CI = 0.67 to 0.75) compared with clinical models (overall breast cancer: C-index = 0.59-0.68; invasive breast cancer: C-index = 0.60-0.68). MIRAI's calibration for risk of overall breast cancer (observed-to-expected ratio = 0.96, 95% CI = 0.85 to 1.08) was improved compared with Gail (observed-to-expected ratio = 1.22, 95% CI = 1.07 to 1.38) and Breast Cancer Surveillance Consortium (observed-to-expected ratio = 1.38, 95% CI = 1.22 to 1.56) but similar to TC with volumetric percent density and polygenic risk score (observed-to-expected ratio = 0.99, 95% CI = 0.87 to 1.13). However, for low-risk women (approximately 50%), MIRAI overestimated risk of overall breast cancer. MIRAI also overestimated risk of invasive breast cancer across the risk spectrum (observed-to-expected ratio = 0.68, 95% CI = 0.58 to 0.78), whereas clinical models had good calibration (observed-to-expected ratio = 0.86-0.99). CONCLUSION: MIRAI demonstrated stronger discriminatory accuracy than clinical models for 5-year overall and invasive breast cancer risk prediction but overestimated risk for both breast cancer endpoints. AI-based risk models should consider discriminatory accuracy and calibration for invasive cancer before implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI for Breast Cancer Risk Prediction Beyond Breast Density.Journal of the Korean Society of Radiology · 2026
- AI-based BRAIx risk score for the intermediate-term prediction of breast cancer: a population cohort studyThe Lancet Digital Health · 2026
- Mammogram-Based Artificial Intelligence Risk Assessment in High-Risk Women Undergoing Supplemental Screening with MRI.Journal of breast imaging · 2026
- BREST-AI: Three-year breast cancer risk prediction from screening mammogramsnpj Breast Cancer · 2026
- Comparison of Artificial Intelligence Detection and Short-Term Breast Cancer Risk Models within and beyond Their Intended Use in Mammography Screening.Radiology. Imaging cancer · 2026
- Deep learning on histopathological images to predict breast cancer recurrence risk and chemotherapy benefit: a multicentre, model development and validation studyThe Lancet Oncology · 2026