Electrocardiographic screening for left atrial enlargement in dogs: derivation and validation of an algorithm combining lead II P-wave duration and the Morris index.
José Luís de Sousa Santana, Marina Pinto Sanches, Laecio da Silva Moura, Yanca Bizerra Souza, Renan Paraguassu de Sá Rodrigues, Ycaro Kylldary Macedo, Eduardo Antônio Lima Oliveira, Bruno Leandro Maranhão Diniz,
Postgraduate Program in Technologies Applied to Animals of Regional Interest (PPGTAIR), Federal University of Piauí (UFPI), Teresina, Piauí, Brazil. · Veterinary Medicine Course (DMV), Federal University of Cariri, Crato, Ceará, Brazil.
Key points
From the paper's conclusion- The algorithm provided complementary detection of left atrial enlargement and reproducible measurements across observers, supporting further evaluation as an adjunct to echocardiographic triage.
Abstract
Combining electrocardiographic measurements may improve identification of dogs requiring echocardiographic assessment. This retrospective diagnostic accuracy study derived a three-category algorithm in 150 dogs and evaluated it in 50 separate validation dogs. Three observers independently measured lead II P-wave duration and the V1 Morris index, with observer A providing the primary analysis. Left atrium-to-aorta ratio (LA/Ao) ≥ 1.6 was the primary outcome; normalized left ventricular internal diameter in diastole (LVIDDN) ≥ 1.7 was evaluated independently as a secondary outcome. Thresholds from 114 reference dogs were 48 and 52 ms for P duration and 3.04 mV·ms for Morris. Positive triage comprised intermediate and high categories. Primary-outcome sensitivity and specificity were 90.6% and 50.0% in derivation and 100% and 85.7% in validation. Validation sensitivity had a 95% confidence interval of 88.1%-100%. The ordinal algorithm area under the curve was 0.961 in validation, compared with 0.868 for P and 0.844 for Morris; paired differences were not significant after Holm adjustment. Secondary-outcome validation sensitivity and specificity were 88.0% and 60.0%. The algorithm provided complementary detection of left atrial enlargement and reproducible measurements across observers, supporting further evaluation as an adjunct to echocardiographic triage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ECG-LabWAS: A Laboratory-Wide Association Study Using a Fine-Tuned Single-Lead Electrocardiogram Foundation ModelarXiv · 2026
- Diagnostic Accuracy of 12-Lead ECG Algorithms for Accessory Pathway Localization in WPW: A Meta-Analysis.Pacing and clinical electrophysiology : PACE · 2026
- P-Wave indices in the presence of atrial myxomas: a retrospective cohort analysis.Clinical research in cardiology : official journal of the German Cardiac Society · 2026
- Directional discordance between a deployed commercial 12-lead ECG interpretation algorithm and expert cardiologists, and its distribution by sex and age: a post-deployment audit using PTB-XL.Physiological measurement · 2026
- A screening method for aortic valve disease based on spectral analysis of a single-channel electrocardiogram using machine learning algorithms.Frontiers in cardiovascular medicine · 2026