ECG-LabWAS: A Laboratory-Wide Association Study Using a Fine-Tuned Single-Lead Electrocardiogram Foundation Model
Wenhui Liu, Yujie Xiao, Gongzheng Tang, Jianwei Chen, Jun Li, Guangkun Nie, Deyun Zhang, Qinghao Zhao,
Key points
From the paper's conclusion- We conducted an exploratory ECG laboratory-wide association study (ECG-LabWAS), fine-tuning an ECG foundation model pretrained on 10.8 million ECGs to screen 50 laboratory tests from single-lead waveforms alone.
Abstract
Laboratory testing guides clinical diagnosis but requires blood sampling and processing. The electrocardiogram (ECG) is fast and noninvasive and may carry information about laboratory abnormalities, yet most AI-ECG models target one test at a time using 12-lead recordings. We conducted an exploratory ECG laboratory-wide association study (ECG-LabWAS), fine-tuning an ECG foundation model pretrained on 10.8 million ECGs to screen 50 laboratory tests from single-lead waveforms alone. The model was developed in an emergency-department cohort (MC-MED; 31,826 patients) and applied unchanged to an independent hospital cohort (MIMIC-IV; 115,921 patients). Of 89 abnormality directions (low or high values of each test), 33 met the same screening criteria in both cohorts. Areas under the receiver operating characteristic curve in the two cohorts were 0.841 and 0.838 for elevated NT-proBNP, 0.769 and 0.740 for elevated cardiac troponin, 0.755 and 0.731 for elevated creatinine, and 0.713 and 0.710 for low potassium. Discrimination changed little when the ECG--laboratory matching window was widened from $\pm$1 to $\pm$24 hours. Model predictions reproduced the co-occurrence of observed abnormalities but were about twice as tightly coupled, largely along one shared component consistent with overall illness severity; low potassium, elevated NT-proBNP and troponin, and markers of renal function retained discrimination beyond that of correlated tests. In exploratory analyses, ECG-assisted versions of the modified Glasgow Prognostic Score and the systemic inflammatory response syndrome criteria were associated with in-hospital and one-year mortality. These results identify which laboratory abnormalities warrant analyte-specific study with single-lead ECG.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence‐Enabled ECG for Elevated E/e' on Echocardiography: Hemodynamic Relevance and Prognostic ValueJournal of the American Heart Association · 2026
- Artificial intelligence-enabled electrocardiography for estimating left ventricular filling pressureEuropean Heart Journal · 2026
- ECG for laboratory values:A comprehensive physiological and technical analysisarXiv · 2026
- A Foundation Transformer Model with Self-Supervised Learning for ECG-Based Assessment of Cardiac and Coronary FunctionNEJM AI · 2025
- Detecting low left ventricular ejection fraction from ECG using an interpretable and scalable predictor-driven framework: a model development and validation studyEClinicalMedicine · 2026
- AI-Assisted Multilabel Diagnosis of 12-Lead Electrocardiograms Using an Interpretable Stacked Deep Learning Model with External Validation.Diagnostics (Basel, Switzerland) · 2026