Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial.
Emma Bamford, Hannah Berntsson, Suzanne Beale, Freya Marks, Lauren Desoysa, Joseph Dias, Sienna Hamer-Kiwacz, Charlotte Head,
Pulvertaft Hand Centre, Royal Derby Hospital, University Hospitals of Derby and Burton NHS Foundation Trust, Derby DE22 3NE, UK emma.bamford1@nhs.net. · Clinical Trials Research Unit (CTRU), Sheffield Centre for Health and Related Research, Division of Population Health, School of Medicine and Population Health, University of Sheffield, Sheffield, UK.
Key points
From the paper's conclusion- This trial found no statistically significant difference in clinical effectiveness between the long, short, and mini splint. Apart from some small differences, secondary outcomes were comparable across all three groups.
Abstract
OBJECTIVE: To compare the clinical effectiveness of three splints after repair of zone 1 and 2 flexor tendons: forearm based (long), Manchester short (short), and relative motion flexion (mini) splints. DESIGN: Prospective, randomised, parallel group, pragmatic, superiority, clinical trial. SETTING: 26 UK hospitals. PARTICIPANTS: 430 participants (aged ≥16 years) requiring rehabilitation after primary repair of zone 1 and 2 flexor tendons in one or two fingers of the hand according to British Society for Surgery of the Hand guidelines. INTERVENTIONS: Participants were randomly assigned 1:1:1 to the long, short, or mini splint. Splints were worn continuously for five weeks and intermittently for a further week at night and in vulnerable situations such as public environments. Masking participants was not possible owing to the nature of the intervention. MAIN OUTCOME MEASURES: The primary outcome was the mean post-randomisation score on the patient-rated wrist and hand evaluation (PRWHE) instrument at 6, 12, 26, and 52 weeks, analysed by intention to treat. RESULTS: 430 participants were randomised to the long splint (n=143), short splint (n=140), or mini splint (n=147) and 403 were included in the intention-to-treat analysis. Adherence, defined as wearing the splint for a minimum of five weeks, was 83% (118/143) for the long splint, 76% (106/140) for the short splint, and 78% (115/147) for the mini splint. Mean post-randomisation PRWHE scores were 24.5 (standard deviation 15.5) in the long splint group, 23.5 (16.7) in the short splint group, and 22.4 (15.0) in the mini splint group, with adjusted between group differences of 0.3 (98.3% confidence interval -4.0 to 4.6, P=0.88) for the long versus short splint, 2.3 (-1.9 to 6.5, P=0.19) for the long versus mini splint, and 2.0 (-2.2 to 6.3, P=0.25) for the short versus mini splint. Serious adverse event rates occurred in 10% (14/143) of participants in the long splint group, 11% (15/140) in the short splint group, and 11% (16/147) in the mini splint group. CONCLUSION: This trial found no statistically significant difference in clinical effectiveness between the long, short, and mini splint. Apart from some small differences, secondary outcomes were comparable across all three groups. TRIAL REGISTRATION: ISRCTN Registry ISRCTN10236011.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Immobilisation versus early active motion following primary flexor pollicis longus tendon zones 1-2 repair: protocol for a registry-based multicentre randomised controlled trial in Sweden.BMJ open · 2026
- Differential Splinting After Zone II Flexor Tendon Repair: The Bidirectional Splint.Plastic and reconstructive surgery. Global open · 2026
- A New Accessible Six-Strand Flexor Tendon Repair Technique: A Four-Group Comparative Study on a Porcine Model.Journal of clinical medicine · 2026
- Impact of early versus delayed mobilization after arthroscopic rotator cuff repair in small and medium-sized tears: a prospective randomized study.Journal of orthopaedic surgery and research · 2026
- Evaluation of Tendon Fastener Designed for Percutaneous Placement in an Ovine Model for Repair of Articular-Sided Rotator Cuff Tears.Journal of functional biomaterials · 2026
- Evaluation of Barbed Suture in Side-to-Side Tendon Transfer Technique Using a Cadaveric Model.Hand (New York, N.Y.) · 2026