Evaluation of Barbed Suture in Side-to-Side Tendon Transfer Technique Using a Cadaveric Model.
Kelly E Jacoby, Jordan Blough, Mei Wang, Patrick Hettinger, Jessica Hanley
Medical College of Wisconsin, Milwaukee, USA.
Key points
From the paper's conclusion- Both STS techniques demonstrated ultimate loads substantially greater than the 15 to 35 N forces reported during passive motion and early active postoperative flexor tendon rehabilitation protocols; however, barbed constructs were approximately 33% weaker and less stiff than cross-stitch repair despite reduced operative time. Although barbed STS repair may have utility in select situations, running cross-stitch repair remains the biomechanical benchmark, and further optimization and clinical validation of barbed constructs are needed before broader adoption.
Abstract
BACKGROUND: To evaluate the biomechanical performance and efficiency of a barbed, knotless side-to-side (STS) tenorrhaphy versus a traditional running cross-stitch STS repair in a cadaveric tendon transfer model. METHODS: Flexor digitorum superficialis and profundus tendons (index, middle, and ring) from 5 fresh-frozen male cadaveric forearms (mean age 52.2 years) were harvested and randomized into 2 groups (n = 12/group). Each pair underwent a 3-cm overlap STS tenorrhaphy with either cross-stitch with a 3-0 braided polyester (Ethibond) or barbed running grasping repair with 2-0 barbed monofilament PDS (Stratafix). After 200 preconditioning cycles at 0.5 Hz to 10% strain (≤30 N), constructs were pulled to failure at 1 mm/s. Primary outcomes were ultimate load and stiffness; secondary outcomes included force reduction after cyclic loading and operative time. RESULTS: All failures occurred at the repair. Mean ultimate load was lower with barbed versus cross-stitch (111.4 ± 26.1 N vs 166.7 ± 34.4 N; P < .002); stiffness was also lower (8.0 ± 2.3 vs 11.9 ± 2.4 N/mm; P < .0006). Displacement at failure was similar (~19-20 mm). Force reduction with cyclic loading did not differ (39% ± 11% vs 34% ± 16%). Barbed repair time was 27.2% shorter (199 vs 272 seconds). CONCLUSION: Both STS techniques demonstrated ultimate loads substantially greater than the 15 to 35 N forces reported during passive motion and early active postoperative flexor tendon rehabilitation protocols; however, barbed constructs were approximately 33% weaker and less stiff than cross-stitch repair despite reduced operative time. Although barbed STS repair may have utility in select situations, running cross-stitch repair remains the biomechanical benchmark, and further optimization and clinical validation of barbed constructs are needed before broader adoption.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A New Accessible Six-Strand Flexor Tendon Repair Technique: A Four-Group Comparative Study on a Porcine Model.Journal of clinical medicine · 2026
- Knot-Dependent Constructs Show Narrowly Better Ultimate Failure Loads Than Knotless Constructs in Proximal Biceps Tenodesis: A Systematic Review and Meta-analysis.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026
- Biomechanical Analysis of Rotator Cuff Repair: Comparison of Sutures and Fixation Techniques in a Synthetic Model.Cureus · 2026
- Evaluation of a novel strap fixation method for biomechanical testing of sheep Achilles tendons.Archives of orthopaedic and trauma surgery · 2026
- A Novel Flexor Tendon Reconstruction Technique in Children: A Potential Solution for a Rare Problem.Journal of pediatric orthopedics · 2026
- Biomechanical comparison of innovative suture techniques for repair of Achilles tendon rupture in a porcine flexor tendon model.Archives of orthopaedic and trauma surgery · 2026