Promise and challenges of heart chamber segmentation from noncontrast CT scans using contrastive unpaired image translation: a feasibility study
Jing Wang, Tong Yu, Hao-En Lu, Zixue Zeng, Xin Meng, Jiantao Pu
University of Pittsburgh
Key points
From the paper's conclusion- ChameleonNet demonstrated feasibility for heart chamber segmentation from noncontrast CT without manual noncontrast annotations. However, volume errors, particularly for LV and RV, indicate that further refinement and validation are needed before clinical use.
Abstract
PurposeTo evaluate the feasibility and challenges of heart chamber segmentation from noncontrast CT scans using contrastive unpaired image translation and deep learning-based segmentation.ApproachWe developed ChameleonNet, a framework utilizing the Contrastive Unpaired Translation (CUT) network with decoupled contrastive learning (DCL) loss to synthesize noncontrast CT from contrast CT scans. Using annotations of four heart chambers (left atrium (LA), left ventricle (LV), right atrium (RA), and right ventricle (RV)) from contrast scans, we trained a Hausdorff distance loss-enhanced nnU-Net on synthesized noncontrast images. The translation model was trained with 35,538 contrast-enhanced and 37,197 noncontrast CT slices. The segmentation model was trained with 292 synthesized noncontrast scans. Performance was evaluated using Dice similarity coefficient (DSC) and 95th Hausdorff distance (HD95) on 36 synthesized noncontrast scans, and volume agreement on 36 real noncontrast CT scans was assessed using Pearson correlation, mean absolute percentage error (MAPE), and mean percentage error (MPE).ResultsThe segmentation model achieved DSC of 0.94 (±0.01), 0.91 (±0.04), 0.92 (±0.03), 0.93 (±0.02), and HD95 of 3.63 (±1.49), 5.74 (±4.08), 5.18 (±1.77), and 5.51 (±3.21) mm on synthesized noncontrast images for LA, LV, RA, and RV, respectively. On real noncontrast CT scans, Pearson correlations were 0.93, 0.82, 0.87, and 0.89 (all p<0.001), with MAPE ranging from 9.22% to 20.79%, and MPE ranging from −12.52% to 4.67%.ConclusionsChameleonNet demonstrated feasibility for heart chamber segmentation from noncontrast CT without manual noncontrast annotations. However, volume errors, particularly for LV and RV, indicate that further refinement and validation are needed before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Exploratory thyroid ultrasound-computed tomography synthesis using anatomy-preserving contrastive unpaired translation.Biomedizinische Technik. Biomedical engineering · 2026
- CoBiDiff: Anatomy-aware bidirectional diffusion for left atrium cross-modal augmentationMeasurement Science and Technology · 2026
- Anatomy-Preserving Unpaired Medical Image Translation via Shared Latent AnchoringarXiv · 2026
- LV-CARE-Diff: A Conditional Anatomy-Aware Diffusion Model for Left Ventricular Shape Reconstruction and Function Quantification from Ultra-Sparse Cine SlicesarXiv · 2026
- Structural-preserving diffusion generation for zero-shot CECT-to-NCCT synthesis.Artificial intelligence in medicine · 2026
- Frequency-consistent synthesis and selective transfer for medical image analysisarXiv · 2026