Measurement Science and Technology

CoBiDiff: Anatomy-aware bidirectional diffusion for left atrium cross-modal augmentation

Ze Zhang, Qince Li, Wei Wang, Yongfeng Yuan, Kuanquan Wang, Gongning Luo

Key points

From the paper's conclusion
  • To overcome this limitation, we propose CoBiDiff, a collaborative bidirectional diffusion framework that explicitly incorporates anatomical constraints into unpaired cross-modal cardiac image augmentation.

Abstract

Accurate delineation of the left atrium (LA) from cardiac magnetic resonance (MR) and computed tomography (CT) images plays an important role in atrial fibrillation (AF) assessment and treatment planning. However, the limited availability of expert-annotated cardiac datasets restricts the robustness and generalizability of deep learning–based segmentation models, particularly in cross-modal scenarios. To overcome this limitation, we propose CoBiDiff, a collaborative bidirectional diffusion framework that explicitly incorporates anatomical constraints into unpaired cross-modal cardiac image augmentation. The framework is developed using unpaired CT and MR volumes from the MICCAI 2017 Multi-Modality Whole Heart Segmentation (MM-WHS) challenge dataset, focusing specifically on the LA region. A shared diffusion backbone is employed to jointly model both imaging modalities, while signed distance functions (SDFs) are incorporated as structural representations to provide anatomical guidance during generation. To reduce the influence of artificial CT field-of-view (FOV) boundaries, boundary regions are suppressed through noise replacement and gradient smoothing strategies. In addition, a soft spatial extent loss is introduced to maintain anatomically plausible foreground spatial extents during synthesis. An SDF dropout strategy is further introduced during training to strengthen image-conditioned anatomical inference and improve anatomical coherence. Experimental results indicate that the proposed framework generates LA images with improved structural consistency across modalities. The proposed method achieved Dice coefficients (DCs) of 86.53% and 95.04%, and average symmetric surface distances (ASSDs) of 1.511 mm and 0.623 mm for CT-to-MR and MR-to-CT augmentation, respectively, on the MM-WHS 2017 dataset. CoBiDiff provides a practical framework for expanding limited cardiac imaging datasets without requiring paired cross-modal images. By combining diffusion-based synthesis with anatomy-aware constraints, CoBiDiff improves the downstream utility of generated samples for cardiac segmentation. The full implementation is publicly available at https://github.com/PencilSC/CoBiDiff to support reproducible and open research.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

CoBiDiff: Anatomy-aware bidirectional diffusion for left atrium cross-modal augmentation — Science Skim