Structural-preserving diffusion generation for zero-shot CECT-to-NCCT synthesis.
Yiwen Zhang, Chuanpu Li, Jinlong Zhang, Liming Zhong, Ruolin Xiao, Wei Yang
Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China. Electronic address: whisneyzyw@gmail.com. · School of Biomedical Engineering, Southern Medical University, Guangzhou, 510515, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Guangzhou, 510515, China. Electronic address: lichuanpugm@gmail.com.
Key points
From the paper's conclusion- Specifically, our SPDG is a guided diffusion generation method that uses the generative prior of the diffusion model and exploits structure-dependent guidance functions to achieve CECT-to-NCCT synthesis.
Abstract
Contrast-enhanced and non-contrast computed tomography (CECT/NCCT) are widely used in various clinical scenarios. CECT-to-NCCT synthesis enables NCCT images to be directly generated from CECT images. This streamlines clinical workflows, reduces radiation exposure risk, and prevents co-registration errors. However, to learn the mapping relationship between CECT and NCCT images, existing CECT-to-NCCT synthesis methods typically require supervised settings, which are reliant on substantial paired data. In this paper, we propose a structural preservation diffusion generation (SPDG) method for zero-shot CECT-to-NCCT synthesis. SPDG does not rely on paired data and can be implemented on a pretrained vanilla diffusion model, utilizing an inference-only process to generate NCCT images. Specifically, our SPDG is a guided diffusion generation method that uses the generative prior of the diffusion model and exploits structure-dependent guidance functions to achieve CECT-to-NCCT synthesis. Using guide images from CECT, we design consistency guidance and smoothness constraints as guidance functions for NCCT image generation. Based on the distribution characteristics of the enhanced regions in CECT images, we split the image into a potential enhancement region and an intensity stable region, and designed specific consistency guiding functions for each. The SPDG method is evaluated on abdomen and head and neck datasets, and the results demonstrate that state-of-the-art performance is achieved in unsupervised CECT-to-NCCT synthesis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Synthetic CT Pulmonary Angiography From Non-Contrast CT.Journal of imaging informatics in medicine · 2026
- Mask-Guided Two-Stage Synthesis and Regional Quantitative Evaluation of Virtual Contrast-Enhanced Thoracic CT.Diagnostics (Basel, Switzerland) · 2026
- L0-Norm-Based CycleGAN for Unpaired Brain CT-to-MR SynthesisarXiv · 2026
- Uncertainty as a Proxy for Semantic Correctness in Diffusion-Based Medical Image SynthesisarXiv · 2026
- Dual-domain latent alignment for MRI-to-CT synthesis via target-aware manifold learning.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2026
- Structure-constrained language-assisted diffusion model for unpaired low-dose computed tomography angiography reconstruction.Neural networks : the official journal of the International Neural Network Society · 2026