Effects of Swelling on Nanomechanical Properties of Corneal Lamellae: Assessed by AFM.
Yingnan Zhai, Beste Caner, Kenia Nunes, Pengfei Dong, Linxia Gu
Department of Biomedical Engineering and Science, Florida Institute of Technology, Melbourne, Florida, 32901, USA.
Key points
From the paper's conclusion- These results indicate that immediate testing after cryosectioning may better preserve nanomechanical integrity.
Abstract
The cornea exhibits significant swelling behavior during mechanical characterization in a liquid environment. This technical brief quantified the impact of swelling on nanomechanical characterization during atomic force microscopy (AFM) test. Corneal sections from the African green monkey were tested in this study. Results showed that lamellar stiffness in swollen corneal section was slightly lower than that in controls, particularly in the anterior and posterior regions (172.4 ± 107.8 kPa and 107.6 ± 69.3 kPa vs. 221.7 ± 62.5 kPa and 124.3 ± 42.2 kPa, respectively), while the middle region remained nearly unchanged (105.9 ± 30.1 kPa vs. 116.2 ± 44.3 kPa); however, these differences were not statistically significant (p > 0.05). These results indicate that the increased interlamellar spacing leads to a larger thickness, which likely contributes to reduced bulk stiffness measured by uniaxial testing. During AFM testing in liquid, adhesion between the tissue section and the glass slide mechanically constrained free swelling. In addition, 14 days of frozen storage at -20 °C significantly increased lamellar stiffness in both control and swollen corneal sections. After storage, control corneal section exhibited stiffness values of 307.7 ± 103.4 kPa, 161.4 ± 30.6 kPa, and 171.9 ± 52.0 kPa at the anterior, middle, and posterior regions, respectively, and 268.8 ± 154.0 kPa, 163.1 ± 101.5 kPa, and 163.2 ± 72.0 kPa in the swollen corneal section. These results indicate that immediate testing after cryosectioning may better preserve nanomechanical integrity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microstructure-dependent biomechanical heterogeneity in irises using atomic force microscopy.Nanoscale advances · 2026
- Regional variations in the biomechanical properties of the isolated porcine retina: potential implications for subretinal injection.Experimental eye research · 2026
- Nanoscale Biomechanical Remodeling in Human Myopic Corneal Lenticule Revealed by Quantitative Dynamic AFM.Biophysical reports · 2026
- Non-contact optical coherence elastography with motion-artifact correction and curvature compensation for quantitative assessment of in vivo keratoconus biomechanicsBiomedical Optics Express · 2026
- Atomic Force Microscopy-Based Nanomechanical Profiling Reveals Oxidative Stress-Associated Structural Alterations and Curcumin-Associated Protection in Chicken Erythrocytes.Current issues in molecular biology · 2026
- Effect of liquid rubber coating on hydration, mechanical properties and strain measurement in biomechanical testing of bone.Biomedizinische Technik. Biomedical engineering · 2026