Effect of liquid rubber coating on hydration, mechanical properties and strain measurement in biomechanical testing of bone.
Markus Greinwald, Sarah Stoiber, Peter Augat
Institute for Biomechanics, BG Unfallklinik Murnau, Murnau, Germany.
Key points
From the paper's conclusion- The liquid-rubber-coating substantially reduced moisture loss and maintained bone mechanical properties over 21 h, without significant alteration to mechanical properties. DIC performance showed no consistent coating-related differences, indicating the coating as a time-stable, water-impermeable alternative to acrylics. Notably, coated samples exhibited reduced odour. Future work should test liquid-rubber-coatings under physiological loading in human bone to improve DIC accuracy for finite element validation and digital twin precision.
Abstract
OBJECTIVES: This study evaluates liquid-rubber-coating to prevent moisture loss in bone during long-term biomechanical testing and digital image correlation (DIC) measurements. Can liquid-rubber-coating preserve bone mechanical properties and enhance DIC measurements? METHODS: Two experimental series used porcine femora in a 4-point-bending setup (n=6). Series 1 compared dehydration with and without rubber-coating during a 21-h drying period, focusing on bending stiffness and weight loss. Series 2 compared liquid-rubber-coating to acrylic-paint for DIC measurements across 50-2,000 µε principal strain. RESULTS: After 21 h, weight loss of the uncoated samples was almost three times higher (7.9 ± 0.4 % vs. 2.9 ± 0.6 %, p<0.001). Bare samples increased bending stiffness by 16.3 ± 4.7 % (p=0.003) vs. 5.8 ± 4.0 % (p=0.155) with coating. DIC noise was 174 ± 121 µε with acrylic-coating and 158 ± 113 µε with liquid-rubber (p=0.700). Bland-Altman analysis showed no significant differences between the groups (p≥0.128). CONCLUSIONS: The liquid-rubber-coating substantially reduced moisture loss and maintained bone mechanical properties over 21 h, without significant alteration to mechanical properties. DIC performance showed no consistent coating-related differences, indicating the coating as a time-stable, water-impermeable alternative to acrylics. Notably, coated samples exhibited reduced odour. Future work should test liquid-rubber-coatings under physiological loading in human bone to improve DIC accuracy for finite element validation and digital twin precision.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of n-Butyl Cyanoacrylate Coating on the Microhardness of MM-MTA After Exposure to Moisture and Human Blood.Journal of functional biomaterials · 2026
- Effects of Swelling on Nanomechanical Properties of Corneal Lamellae: Assessed by AFM.Journal of biomechanical engineering · 2026
- Contact-Free Mechanical Mapping of 3D Microprinted Hydrogels Using FLIM.Small methods · 2026
- Two-laboratory comparability of apparent elastic modulus measurements in bovine lumbar vertebral trabecular bone under a standardized compression protocol.Journal of biomechanics · 2026
- Radial Water Loss Assay in Rice Roots Grown in Different Media.Bio-protocol · 2026
- Regional variations in the biomechanical properties of the isolated porcine retina: potential implications for subretinal injection.Experimental eye research · 2026