Refractive Error Measurement Comparison Between Two Techniques, HandyRef‐K Handheld Refractometer Versus Streak Retinoscopy, in Normal Dogs
T. E. Leite, M. Kaminsky, P. Gordon‐Ross, K. Adams
Key points
From the paper's conclusion- Overall, cycloplegia did affect RE measured in the dog.
Abstract
Objective To compare Nidek's HandyRef‐K autorefractometer (HRK) to streak retinoscopy (SR) refractive error (RE) in dogs pre‐ and post‐cycloplegia. Animals Studied Twenty‐two normal dogs. Procedures The RE was determined by an expert and a novice examiner utilizing both techniques before and after administration of Tropicamide 1%. A linear mixed‐effects model was used to evaluate the effects of examiner, technique, dilation status, and eye on RE measurements and interactions. Patient was included as a random effect, and patient order was included as a covariate to assess potential evaluator learning effects. Results Analysis revealed statistically significant differences by the technique used [ F (1, 20) = 20.482, p < 0.001, partial η 2 = 0.506], and RE measured by HRK was on average 0.821 diopters (D) more hyperopic than SR. Dilation status [ F (1, 20) = 8.196, p = 0.010, partial η 2 = 0.291] was statistically significant, indicating a cycloplegic eye's RE was +0.165 D greater than the non‐cycloplegic measurement. No statistically significant difference by examiner was observed in non‐cyclopleged eye ER measured with SR [ t (43) = −0.399, p = 0.692, d = −0.060] and HRK [ t (43) = 0.974, p = 0.335, d = 0.147] nor in cyclopleged eye ER measurements with SR [ t (43) = −1.665, p = 0.103, d = −0.251] and HRK [ t (43) = 0.041, p = 0.968, d = 0.006]. Conclusion Good agreement between the two examiners' RE measurements was present regardless of the cycloplegic state and technique being used. When comparing pre‐ and post‐cycloplegia values, HRK tended to overestimate hyperopia for both examiners. Overall, cycloplegia did affect RE measured in the dog. The difference in spherical equivalent was greatest for each examiner when comparing a dog's pre‐cycloplegic SR measurements to its post‐cycloplegic HRK RE measurement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Variability in Refractive Measurements in Children with Autism Spectrum Disorder Under Cycloplegic and Non-Cycloplegic Conditions: Influence of Measurement Method.Journal of clinical medicine · 2026
- The effect of cycloplegia on corneal power and diameter measured by an auto-kerato-refractometer in presbyopic patients with type 2 diabetes mellitus: a post-hoc analysis of a randomized clinical trial.BMC ophthalmology · 2026
- Comparison of refractive error measurements obtained with a pyramid wavefront sensor topo-aberrometer and an auto kerato-refractometer against subjective refraction.Clinical & experimental optometry · 2026
- Comparison of Refraction Obtained with the Myopia Master and Subjective Manifest Refraction in Pediatric Orthokeratology.Diagnostics (Basel, Switzerland) · 2026
- Effect of fogging lenses on accommodation using an open-view portable wavefront autorefractor.Journal of optometry · 2026
- The Repeatability and Agreement of Two SS-OCT Optical Biometers in Adult Eyes Undergoing Cataract Surgery.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026