Residual Positive Buttress Displacement After Femoral Neck System Fixation for Acute Femoral Neck Fractures: A Retrospective Cohort Study.
Jian Xing, Yanan Ren, Pengfei Wang, Kun Zhang
General Division of Orthopedic Trauma Department, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China.
Key points
From the paper's conclusion- Methods This retrospective cohort study included 180 adults with isolated acute femoral neck fractures treated with femoral neck system fixation between September 1, 2023, and April 30, 2024, and followed for at least 12 months.
Abstract
OBJECTIVE: When anatomical reduction cannot be safely achieved, the functional relevance of residual positive-buttress displacement after FNS fixation remains uncertain. Few clinical studies have quantified how its magnitude relates to hip function. To determine whether hip function after femoral neck system fixation differs by postoperative reduction pattern and, within positive-buttress reduction, by residual medial cortical displacement. METHODS: This retrospective cohort study included 180 adults with isolated acute femoral neck fractures treated with femoral neck system fixation between September 1, 2023, and April 30, 2024, and followed for at least 12 months. The overall analysis included Garden I-IV fractures; the exploratory five-group displacement analysis was restricted to Garden I-III fractures. Postoperative reduction was classified as anatomical reduction, positive-buttress reduction, or negative-buttress reduction. Positive-buttress displacement was measured on anteroposterior radiographs and categorized as PR-2 (≤ 2 mm), PR-4 (> 2-4 mm), or PR-6 (> 4 mm). The primary outcome was 12-month Harris Hip Score. Group comparisons used one-way analysis of variance, Kruskal-Wallis tests, chi-square or exact tests, and multivariable linear regression. Multivariable linear regression adjusted for age, sex, and Garden classification. Additional analyses evaluated continuous displacement, retained Garden IV fractures in the five-group comparison, and incorporated the available clinical covariates. RESULTS: The cohort included 45 anatomical, 98 positive-buttress, and 37 negative-buttress reductions. Median 12-month Harris Hip Score was 95.8, 86.0, and 69.5, respectively. Compared with anatomical reduction, adjusted Harris Hip Score was lower by 9.40 points in positive-buttress reduction and 25.62 points in negative-buttress reduction. In the exploratory analysis restricted to Garden I-III fractures, median Harris Hip Score declined across anatomical reduction, PR-2, PR-4, PR-6, and negative-buttress reduction (95.8, 90.0, 80.0, 74.0, and 68.9). Among the 82 positive-buttress cases in this restricted analysis, each additional millimeter of displacement was associated with a 3.89-point lower score (95% confidence interval, 3.12-4.66 points lower). The additional five-group analysis retaining Garden IV fractures showed the same direction of association. CONCLUSIONS: In the overall cohort, reduction pattern was associated with 12-month hip function. Garden IV fractures and open reduction were unevenly distributed across reduction patterns, and adjustment cannot eliminate residual confounding from fracture complexity, reduction difficulty, surgeon decisions, and unmeasured factors; these associations do not show that changing reduction pattern improves function. In the exploratory analysis restricted to Garden I-III fractures, PR-2 had the highest 12-month Harris Hip Score among the nonanatomical groups. Larger residual displacement was associated with lower scores, but the findings do not establish a clinical 2-mm threshold or a clinically important PR-2 versus anatomical reduction difference. The additional all-Garden analysis does not constitute separate validation in Garden IV fractures. PR-2, PR-4, and PR-6 were exploratory categories rather than validated clinical thresholds or indications for additional reduction or open surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative efficacy of the femoral neck system, cannulated cancellous screws combined with medial buttress plate, and cannulated cancellous screws in the treatment of femoral neck fractures in young and middle-aged adults.Injury · 2026
- Femoral Neck System for young and middle-aged adult femoral neck fractures: a trade-off between reduced lateral irritation and increased neck shortening.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- Early mechanical failure patterns after femoral neck fixation with the femoral neck system and dynamic hip screw.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Early clinical and radiographic outcomes of robot-assisted femoral neck system fixation combined with an additional cannulated compression screw for garden IV femoral neck fractures in young and middle-aged adults: a propensity score-matched retrospective cohort study.Frontiers in surgery · 2026
- A retrospective cohort study comparing combined TiRobot navigation and percutaneous minimally invasive FNS fixation versus conventional open reduction FNS for femoral neck fractures.Journal of robotic surgery · 2026
- Characteristics of the Extent and Onset of Osteonecrosis of the Femoral Head After Femoral Neck System (FNS) Fixation: A Minimum Two-Year Follow-Up Comparative Study with Cannulated Screws.Journal of clinical medicine · 2026