A Conservative Chairside Technique for Retrieval of a Fractured Implant Abutment Screw Using a Modified Hand Instrument: A Case Report
Bhuvanesh Kumar Dharani Vidhya, Sajida Begum Sekaran, Vignesh Veerakumar, Divyameena Bommiah
Key points
From the paper's conclusion- Clinical Significance The technique described offers a simple, cheap, reproducible, and minimally invasive approach to retrieve fractured implant abutment screws without the use of special ultrasonic devices or retrieval kits.
Abstract
Background The fracture of implant abutment screws is a rare but clinically meaningful intraoral mechanical complication that threatens implant‐supported prostheses; their recovery can be very difficult. Traditional retrieval has its disadvantages, including the need for specific instruments and the risk of damaging internal threads of the implant. This report presents a straightforward, conservative, and low‐cost chairside method of recovering a broken abutment screw with the use of a modified hand instrument. Case Presentation A 46‐year‐old female diagnosed following movement of an implant‐supported crown in the maxillary right central incisor region since a road traffic incident. During clinical and radiographic evaluation, a fractured abutment screw was detected in a well‐osseointegrated internal hex implant. The exposed screw fragment was prepared with a straight fissure carbide bur to create a shallow horizontal groove. A chisel‐shaped hand instrument, improvised from a commonly available dental tool, was inserted into the slot and occupied in the screw groove with controlled anticlockwise motion to retrieve the fractured screw. The integrity of the internal implant threads was confirmed clinically and by an impression of the implant connection. Management and Outcome After retrieval, minor peri‐implant dehiscence was clinically managed with guided bone regeneration, and a dental implant was reinserted at the adjacent edentulous site. Both implants were returned to function at the end of a normal healing period, with screw‐retained prostheses resulting in satisfactory functional and aesthetic outcomes without morbidity. Clinical Significance The technique described offers a simple, cheap, reproducible, and minimally invasive approach to retrieve fractured implant abutment screws without the use of special ultrasonic devices or retrieval kits. Implant–abutment interface preservation reduces the risk of implant damage, enables prosthetic rehabilitation, and serves as an alternative practice in routine clinical procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Abutment Screw Head Design with an Integrated Retrieval Feature: An In Vitro Study.Dentistry journal · 2026
- A Novel Surgical Technique for the Extraction of a Broken, Incarcerated Intramedullary Reamer.Cureus · 2026
- Difficult INFIX screw removal after screwdriver fracture: salvage using an extracorporeal rod-screw complex.International journal of surgery case reports · 2026
- A Stepwise Technique for Retrieval of a Seized and Stripped Dental Implant Cover Screw: A Case Report.Reports (MDPI) · 2026
- CONSERVATIVE MANAGEMENT OF A CERVICALLY FRACTURED ZYGOMATIC IMPLANT USING A NOVEL TITANIUM DEVICE: A TECHNICAL REPORT WITH BIOMECHANICAL VALIDATION AND 24-MONTH FOLLOW-UP.Journal of stomatology, oral and maxillofacial surgery · 2026
- Conservative Custom Wire and Loop-Assisted Retrieval of a Long Separated Instrument Extending Beyond the Apex: A Case Report.Cureus · 2026