Endoscopic Ultrasound-Guided Hepaticogastrostomy With Plastic Stent Versus Metallic Stent for Malignant Biliary Obstruction: A Meta-Analysis.
Hirofumi Yamazaki, Masahiro Itonaga, Ke Wan, Yasunobu Yamashita, Reiko Ashida, Masayuki Kitano
Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan. · Clinical Study Support Center, Wakayama Medical University Hospital, Wakayama, Japan.
Key points
From the paper's conclusion- In this meta-analysis, metal stents showed longer TRBO, lower recurrent biliary obstruction rate, and higher adverse event rate than plastic stents.
Abstract
OBJECTIVES: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is an alternative procedure for malignant biliary obstruction after failure of endoscopic retrograde cholangiopancreatography. When performing EUS-HGS, either plastic or metal stents are used, but selection often depends on the discretion of the endoscopist. We compared the efficacy and safety of plastic and metal stents during EUS-HGS. METHODS: We performed a systematic meta-analysis of all relevant articles listed by searching PubMed, Medline, and Web of Science databases. Random-effects or fixed-effects models were used to compare time to recurrent biliary obstruction (TRBO), clinical success rate, adverse event rate, rate of recurrent biliary obstruction, and re-intervention success rate after EUS-HGS with plastic and metal stents. RESULTS: This meta-analysis included six eligible studies. The TRBO of the metal stent group was significantly longer than that of the plastic stent group (hazard ratio 1.83; 95% confidence interval [CI] 1.42-2.36). The total procedure-related adverse event rate of the metal stent group was significantly higher than that of the plastic stent group (odds ratio [OR] 0.48; 95% CI 0.30-0.77). The recurrent biliary obstruction rate of the plastic stent group was significantly higher than that of the metal stent group (OR 1.75; 95% CI 1.06-2.88). No significant difference was found for the clinical success rate or re-intervention success rate. CONCLUSION: In this meta-analysis, metal stents showed longer TRBO, lower recurrent biliary obstruction rate, and higher adverse event rate than plastic stents.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Reintervention Outcomes After Endoscopic Ultrasound-Guided Hepaticogastrostomy According to the Type of Initial Stent.Journal of clinical medicine · 2026
- Metallic versus plastic stents for the management of biliary obstruction: A GRADE-assessed systematic review and meta-analysis.Medicine · 2026
- Types of Self-Expandable Metal Stents for Palliative Drainage of Unresectable Extrahepatic Malignant Biliary Obstruction: A Network Meta-Analysis of Randomized Controlled Trials.Endoscopy · 2026
- Efficacy of endoscopic ultrasound-guided versus surgical gastrojejunostomy for malignant gastric outlet obstruction: a systematic review and meta-analysis.Frontiers in oncology · 2026
- Electrocautery-Enhanced Lumen-Apposing Metal Stents Versus Modified Tubular Metal Stents for EUS-Guided Gallbladder Drainage: A Multicenter Study.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026
- EUS-Guided Choledochoduodenostomy with Lumen-Apposing Metal Stent versus ERCP with Self-Expandable Metal Stent as Primary Biliary Drainage for Malignant Distal Biliary Obstruction: A Systematic Review and Meta-Analysis of Randomized Controlled TrialsmedRxiv · 2026