Comparison of Reintervention Outcomes After Endoscopic Ultrasound-Guided Hepaticogastrostomy According to the Type of Initial Stent.
Yukari Suzuki, Takashi Sasaki, Tsuyoshi Takeda, Masashi Miura, Masanori Nagasawa, Toyokazu Saito, Yuri Maegawa, Takafumi Mie,
Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo 135-8550, Japan.
Key points
From the paper's conclusion- Background/Objectives: The impact of initial stent type on endoscopic reintervention after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear.
Abstract
Background/Objectives: The impact of initial stent type on endoscopic reintervention after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. Methods: We retrospectively evaluated patients with malignant biliary obstruction who developed recurrent biliary obstruction (RBO) after EUS-HGS and underwent reintervention through the endosonographically created route (ESCR). Outcomes were compared according to initial stent type (plastic stent [PS] or self-expandable metallic stent [SEMS]). The association between initial stent type and time to RBO (TRBO) after definitive biliary drainage was assessed using Cox regression and Fine-Gray regression. Results: Of 170 patients who underwent EUS-HGS, 69 were included (PS, n = 23; SEMS, n = 46). The initial reintervention procedure was technically successful in 100% and 95.7% of patients, respectively (p = 0.55). Definitive biliary drainage was technically successful in all 69 patients, while clinical success was achieved in 62 (89.9%). No procedure-related adverse events were observed. Among patients with clinical success, median TRBO was 160 and 140 days in the PS and SEMS groups, respectively. Initial SEMS placement was not significantly associated with TRBO (adjusted hazard ratio, 1.32; 95% confidence interval [CI], 0.55-3.13) or the cumulative incidence of RBO (adjusted subdistribution hazard ratio, 1.67; 95% CI, 0.70-3.97). Conclusions: Endoscopic reintervention through the ESCR was technically feasible after both initial PS and SEMS placement. Initial stent type was not significantly associated with subsequent RBO, although the findings should be interpreted cautiously because of potential temporal confounding and the limited sample size.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Endoscopic Ultrasound-Guided Hepaticogastrostomy With Plastic Stent Versus Metallic Stent for Malignant Biliary Obstruction: A Meta-Analysis.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026
- Comparison of Uncovered and Covered Biliary SEMS for the Salvage of Obstructed SEMS: A Multicenter Retrospective Propensity Score-Weighted Study.Journal of gastroenterology and hepatology · 2026
- Types of Self-Expandable Metal Stents for Palliative Drainage of Unresectable Extrahepatic Malignant Biliary Obstruction: A Network Meta-Analysis of Randomized Controlled Trials.Endoscopy · 2026
- Outcomes of Different Guidewire-Assisted Techniques for Recurrent Malignant Biliary Obstruction After Uncovered Metallic Stent Placement.Journal of digestive diseases · 2026
- Endoscopic ultrasound-guided transpapillary versus transluminal biliary stenting: randomized comparison of long-term stent patencyEndoscopy · 2025
- Endoscopic self-expandable metal stent placement before conversion therapy for advanced and recurrent gastrointestinal malignancies: A single-center retrospective study.Medicine · 2026