Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society

Electrocautery-Enhanced Lumen-Apposing Metal Stents Versus Modified Tubular Metal Stents for EUS-Guided Gallbladder Drainage: A Multicenter Study.

Dongwook Oh, Yu-Ting Kuo, Yoonchan Lee, Sung Hyun Cho, Gunn Huh, Dong-Wan Seo, Hsiu-Po Wang, Ji Sung Lee,

Department of Gastroenterology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea. · Division of Endoscopy, Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, Taipei, Taiwan.

Observational · n=123

Key points

From the paper's conclusion
  • Both stents achieved similarly high technical and clinical success rates before weighting, while EC-LAMS was associated with substantially shorter procedure time. The higher weighted success estimates with EC-LAMS require cautious interpretation because of the small number of failures and potential residual confounding.

Abstract

OBJECTIVES: Electrocautery-enhanced lumen-apposing metal stents (EC-LAMS) enable single-step deployment for endoscopic ultrasound-guided gallbladder drainage (EUS-GBD), but comparative data with modified tubular metal stents (MTMS) are limited. We compared clinical outcomes between MTMS and EC-LAMS for EUS-GBD. METHODS: We retrospectively analyzed a prospectively maintained multicenter cohort of consecutive patients who underwent EUS-GBD using MTMS or EC-LAMS between January 2022 and August 2024. Technical success was the primary outcome. Secondary outcomes were clinical success, procedure time, early and late adverse events, and recurrent cholecystitis. Propensity score-based overlap weighting was applied. RESULTS: Among 123 patients, 67 received MTMS and 56 received EC-LAMS. Before weighting, technical and clinical success rates did not differ (95.5% vs. 98.2%; p = 0.625 for both), whereas procedure time was shorter with EC-LAMS (7.8 ± 4.1 vs. 2.3 ± 1.8 min; p < 0.001). After weighting, the estimated technical and clinical success rates were both 96.8% with MTMS and 99.8% with EC-LAMS (p = 0.004 for each), and procedure time remained shorter with EC-LAMS (7.8 ± 1.7 vs. 2.5 ± 1.1 min; p < 0.001). Early and late adverse events and recurrent cholecystitis did not differ significantly before or after weighting. CONCLUSIONS: Both stents achieved similarly high technical and clinical success rates before weighting, while EC-LAMS was associated with substantially shorter procedure time. The higher weighted success estimates with EC-LAMS require cautious interpretation because of the small number of failures and potential residual confounding.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Electrocautery-Enhanced Lumen-Apposing Metal Stents Versus Modified Tubular Metal Stents for EUS-Guided Gallbladder Drainage: A Multicenter Study — Science Skim