(Meth)acrylate Allergy in the Era of Nail Cosmetics and Medical Devices: Limitations of HEMA and Optimization of Patch Testing.
Norbertus A Ipenburg, Mounir Yaâkoubi, Anton C de Groot, Thomas Rustemeyer
Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Center, Amsterdam, the Netherlands. · Amsterdam University Medical Center, Amsterdam, the Netherlands.
Key points
From the paper's conclusion- HEMA is not sufficient as a universal screening allergen. Testing can be optimized by tailored, exposure-based allergen panels.
Abstract
BACKGROUND: (Meth)acrylate allergy is increasingly caused by modern exposures such as nail cosmetics and diabetes-related medical devices. The performance of 2-hydroxyethyl methacrylate (HEMA) as a screening allergen and the optimal composition of patch test series remain uncertain. OBJECTIVES: To evaluate patch test results to a (meth)acrylate series, assess the performance of HEMA, analyze co-reactivity patterns, and optimize allergen panels. MATERIALS AND METHODS: A retrospective study was conducted in 955 patients patch tested with a (meth)acrylate series between 2015 and 2025. Frequencies of positive reactions, clinical relevance, causative products, co-reactivity and diagnostic yield of individual allergens were analyzed. RESULTS: Of 955 patients, 176 (18.4%) had ≥ 1 positive reaction. Nail cosmetics (47%) and diabetes devices (15%) were the main sources. HEMA identified 61% of sensitized patients; 39% would have been missed if tested alone, including 32% of clinically relevant cases. Sensitivity varied by exposure, performing well in nail cosmetics (94%) but poorly in diabetes devices (12%) and other categories. Strong clustering and co-reactivity were observed. Complete detection was achieved with 13 haptens, while 6 and 8 identified 90% and 95% of cases. CONCLUSIONS: HEMA is not sufficient as a universal screening allergen. Testing can be optimized by tailored, exposure-based allergen panels.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acrylate Patch Testing for Allergic Contact Dermatitis Over 28 Years: Hierarchical Clustering for Subgroup Analysis and Computational Optimization for Patch Test Selection.Dermatitis : contact, atopic, occupational, drug · 2026
- Beyond HEMA: Shifts in the (Meth)acrylate Composition of Matched Nail Cosmetics Between 2023 and 2026.Contact dermatitis · 2026
- High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets.Contact dermatitis · 2026
- First Cases of Allergic Contact Dermatitis From the New FreeStyle Libre 3 Sensor: Small Device, Multiple Allergens.Contact dermatitis · 2026
- Patch test reactions to dental materialsDiRROS repository (University of Maribor) · 2026
- The Influence of (Meth)acrylates on Occupation-Associated Skin and Mucosal Allergic ReactionsAllergies · 2026