High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets.
Norbertus A Ipenburg, Emma M van Oers, Anton C de Groot, Mounir Yaâkoubi, Thomas Rustemeyer
Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Center, Amsterdam, the Netherlands. · Amsterdam University Medical Centers, Amsterdam, the Netherlands.
Key points
From the paper's conclusion- Objectives To evaluate the diagnostic yield of a dedicated diabetes device screening series, supplemented with a (meth)acrylate series and testing of patients' own device adhesives and adhesive extracts, in patients with suspected allergic contact dermatitis to glucose sensors, insulin patch pumps, or infusion sets.
Abstract
BACKGROUND: Patch testing in patients with dermatitis from diabetes devices is challenging because device composition is nearly always undisclosed, relevant allergens are incompletely known, and many suspected allergens are not commercially available. OBJECTIVES: To evaluate the diagnostic yield of a dedicated diabetes device screening series, supplemented with a (meth)acrylate series and testing of patients' own device adhesives and adhesive extracts, in patients with suspected allergic contact dermatitis to glucose sensors, insulin patch pumps, or infusion sets. MATERIALS AND METHODS: We performed a retrospective patch test study of 100 patients referred to a tertiary referral centre for suspected allergic reactions to diabetes devices. RESULTS: Seventy-one patients reacted to one or more allergens in the diabetes device screening series; in 50 (70.4%), at least one reaction was clinically relevant. The most frequent relevant allergens were colophonium and its related substances abietic acid and hydroabietyl alcohol, isobornyl acrylate, dicyclohexylmethane-4,4'-diisocyanate, and N,N-dimethylacrylamide. The (meth)acrylate series had no clear additional diagnostic value. Testing with patients' own device adhesives and extracts frequently identified allergic reactions to devices not recognised by the results of the screening series alone. CONCLUSION: The combined approach identified relevant contact allergies in most patients with suspected allergic contact dermatitis to diabetes devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- First Cases of Allergic Contact Dermatitis From the New FreeStyle Libre 3 Sensor: Small Device, Multiple Allergens.Contact dermatitis · 2026
- Assessing the Skin Sensitizing Potential of Constituents and Leachables from Wearable Devices Using GARDskin and Associated Applications.Toxics · 2026
- European Society of Contact Dermatitis Guideline for Diagnostic Patch Testing—Recommendations on Best Practice (Update 2026)Contact Dermatitis · 2026
- Acrylate Patch Testing for Allergic Contact Dermatitis Over 28 Years: Hierarchical Clustering for Subgroup Analysis and Computational Optimization for Patch Test Selection.Dermatitis : contact, atopic, occupational, drug · 2026
- Patch test reactions to dental materialsDiRROS repository (University of Maribor) · 2026
- Evaluation of Latex-Specific IgE and Skin Test Results in Patients with Suspected Latex AllergySakarya Medical Journal · 2026