Accuracy and Efficiency of Proprietary Navigation, Haptic, and Optical Robotic Systems: An In Vitro Study
Yixuan Li, Wenying Wang, Yihan Shen, Feng Wang, Baoxin Tao, Yiqun Wu
Key points
From the paper's conclusion- These findings are specific to the systems evaluated and should not be generalized to other systems within the same technological categories.
Abstract
Objectives This study aimed to compare the accuracy and efficiency of three specific proprietary computer‐assisted implant surgery systems representing a dynamic navigation system (DNS), a haptic‐feedback robotic system (HRS), and an optical guided robotic system (ORS). Methods A total of 480 dental implants were placed in 120 mandibular and maxillary models, representing both partially edentulous and completely edentulous conditions. The models were allocated to three proprietary systems representing DNS, HRS, and ORS. Implant platform, apex, and angle deviations were calculated and compared among the three groups. Surgical time was also recorded. A linear mixed‐effects model was used to compare the accuracy and efficiency among these three implant surgery systems. Results Linear mixed‐effects modeling revealed significant differences in performance. For all primary accuracy metrics, including angle, platform, and apex deviations, HRS and ORS demonstrated no statistically significant differences ( p > 0.05); however, both systems demonstrated significantly lower deviations compared to DNS ( p < 0.001). Specifically, deviations for HRS, ORS, and DNS were: (0.95° ± 0.67° vs. 0.85° ± 0.50° vs. 1.37° ± 0.69°) for angle ( p < 0.001); (0.70 ± 0.30 mm vs. 0.65 ± 0.36 mm vs. 1.06 ± 0.44 mm) for platform ( p < 0.001); and (0.76 ± 0.32 mm vs. 0.67 ± 0.38 mm vs. 1.04 ± 0.46 mm) for apex ( p < 0.001), respectively. However, HRS exhibited the shortest pre‐operative (97.7 ± 48.2 s) and placement times (221.0 ± 27.0 s), demonstrating higher efficiency compared to both DNS (269.8 ± 41.7 s; 312.7 ± 49.3 s) and ORS (249.1 ± 56.9 s; 258.0 ± 47.8 s) ( p < 0.001). Conclusions Within the limitations of this in vitro study, all three proprietary systems achieved clinically acceptable accuracy. The tested robotic systems showed lower deviations than the tested DNS, while the HRS demonstrated greater procedural efficiency. These findings are specific to the systems evaluated and should not be generalized to other systems within the same technological categories.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative accuracy of dynamic navigation versus static surgical guides for dental implant placement: an in vitro assessment of free-end and non-free-end configurationsScientific Reports · 2026
- Robotic surgery vs dynamic navigation: does greater accuracy make the difference in implant dentistry?Evidence-based dentistry · 2026
- Accuracy of Planned Versus Actual Implant Placement Using Different Implant Systems: A Systematic Review of Angulation and Positional Deviations.Journal of maxillofacial and oral surgery · 2026
- Advances in artificial intelligence enhanced robotics for dental implant placement: A scoping reviewJournal of Dentistry · 2026
- Dynamic and Robotic Computer‐Assisted Implant Surgery—A Possible Workflow for the Future?Australian Dental Journal · 2025
- Static, Dynamic and Robotic CAIS in Healed Partially Edentulous Sites: Accuracy and Chair‐Side TimeClinical Implant Dentistry and Related Research · 2026