From the paper's conclusion
  • Aim To evaluate the accuracy and chair‐side efficiency of static (s‐CAIS), dynamic (d‐CAIS), and autonomous robotic (r‐CAIS) computer‐assisted implant surgery in healed partially edentulous sites.

Abstract

Aim To evaluate the accuracy and chair‐side efficiency of static (s‐CAIS), dynamic (d‐CAIS), and autonomous robotic (r‐CAIS) computer‐assisted implant surgery in healed partially edentulous sites. Materials and Methods In this retrospective comparative study, 73 patients with 92 implants, treated from September 2022 to October 2024, were included (s‐CAIS: 21 patients/33 implants; d‐CAIS: 29 patients/32 implants; r‐CAIS: 23 patients/27 implants). Pre‐ and postoperative CBCT scans were used to assess linear and angular deviations. The duration of chair‐side preparation and drilling/implant placement was recorded for d‐CAIS and r‐CAIS. Results At implant level, mean platform deviations were 0.85 ± 0.38 mm (s‐CAIS), 1.37 ± 0.71 mm (d‐CAIS), and 0.59 ± 0.32 mm (r‐CAIS; median [IQR]: 0.54 [0.30] mm); apex deviations were 1.36 ± 0.51, 1.48 ± 0.66, and 0.64 ± 0.52 mm (r‐CAIS; median [IQR]: 0.53 [0.30] mm); angular deviations were 4.34° ± 2.13°, 2.53° ± 0.99°, and 1.54° ± 1.50° (r‐CAIS; median [IQR]: 1.28° [1.40°]). At patient level, platform deviations were 0.88 ± 0.35, 1.37 ± 0.69, and 0.57 ± 0.29 mm; apex deviations 1.38 ± 0.44, 1.48 ± 0.65, and 0.58 ± 0.43 mm; angular deviations 4.48° ± 1.81°, 2.52° ± 0.97°, and 1.45° ± 1.30°. r‐CAIS showed significantly superior accuracy compared with s‐CAIS and d‐CAIS ( p < 0.05). Because r‐CAIS data were not normally distributed, medians [IQR] were additionally calculated and are reported parenthetically. Drilling and placement time was longer for d‐CAIS than r‐CAIS (18.06 ± 5.54 vs. 10.81 ± 3.55 min, p < 0.05), while chair‐side preparatory time did not differ (10.78 ± 2.53 vs. 9.61 ± 2.72 min, p > 0.05). Conclusions Among the three systems, r‐CAIS provided the highest accuracy and was more time‐efficient during the intra‐operative (chair‐side) phase than d‐CAIS in partially edentulous patients. Clinical Relevance In patients with partial edentulism, r‐CAIS demonstrated superior accuracy compared with both s‐CAIS and d‐CAIS approaches. Furthermore, r‐CAIS offered greater chair‐side efficiency during the intra‐operative phase than d‐CAIS. This cutting‐edge technology holds great promise for enhancing the precision of dental implant procedures, offering substantial benefits to both surgeons and patients.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Static, Dynamic and Robotic CAIS in Healed Partially Edentulous Sites: Accuracy and Chair‐Side Time — Science Skim