Static, Dynamic and Robotic CAIS in Healed Partially Edentulous Sites: Accuracy and Chair‐Side Time
Xu Zhao, MiaoZhen Wang, Tao Yu, FeiFei Ma, Xiaohui Rausch‐Fan, Feng Liu
Key points
From the paper's conclusion- Aim To evaluate the accuracy and chair‐side efficiency of static (s‐CAIS), dynamic (d‐CAIS), and autonomous robotic (r‐CAIS) computer‐assisted implant surgery in healed partially edentulous sites.
Abstract
Aim To evaluate the accuracy and chair‐side efficiency of static (s‐CAIS), dynamic (d‐CAIS), and autonomous robotic (r‐CAIS) computer‐assisted implant surgery in healed partially edentulous sites. Materials and Methods In this retrospective comparative study, 73 patients with 92 implants, treated from September 2022 to October 2024, were included (s‐CAIS: 21 patients/33 implants; d‐CAIS: 29 patients/32 implants; r‐CAIS: 23 patients/27 implants). Pre‐ and postoperative CBCT scans were used to assess linear and angular deviations. The duration of chair‐side preparation and drilling/implant placement was recorded for d‐CAIS and r‐CAIS. Results At implant level, mean platform deviations were 0.85 ± 0.38 mm (s‐CAIS), 1.37 ± 0.71 mm (d‐CAIS), and 0.59 ± 0.32 mm (r‐CAIS; median [IQR]: 0.54 [0.30] mm); apex deviations were 1.36 ± 0.51, 1.48 ± 0.66, and 0.64 ± 0.52 mm (r‐CAIS; median [IQR]: 0.53 [0.30] mm); angular deviations were 4.34° ± 2.13°, 2.53° ± 0.99°, and 1.54° ± 1.50° (r‐CAIS; median [IQR]: 1.28° [1.40°]). At patient level, platform deviations were 0.88 ± 0.35, 1.37 ± 0.69, and 0.57 ± 0.29 mm; apex deviations 1.38 ± 0.44, 1.48 ± 0.65, and 0.58 ± 0.43 mm; angular deviations 4.48° ± 1.81°, 2.52° ± 0.97°, and 1.45° ± 1.30°. r‐CAIS showed significantly superior accuracy compared with s‐CAIS and d‐CAIS ( p < 0.05). Because r‐CAIS data were not normally distributed, medians [IQR] were additionally calculated and are reported parenthetically. Drilling and placement time was longer for d‐CAIS than r‐CAIS (18.06 ± 5.54 vs. 10.81 ± 3.55 min, p < 0.05), while chair‐side preparatory time did not differ (10.78 ± 2.53 vs. 9.61 ± 2.72 min, p > 0.05). Conclusions Among the three systems, r‐CAIS provided the highest accuracy and was more time‐efficient during the intra‐operative (chair‐side) phase than d‐CAIS in partially edentulous patients. Clinical Relevance In patients with partial edentulism, r‐CAIS demonstrated superior accuracy compared with both s‐CAIS and d‐CAIS approaches. Furthermore, r‐CAIS offered greater chair‐side efficiency during the intra‐operative phase than d‐CAIS. This cutting‐edge technology holds great promise for enhancing the precision of dental implant procedures, offering substantial benefits to both surgeons and patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of Robotic Computer-Assisted Implant Surgery in Fully Edentulous Patients: A Systematic Review and Meta-Analysis.Journal of dentistry · 2026
- Trueness of Dental Implant Placement With Robotic Computer‐Assisted Implant Surgery: A Meta‐Analysis of Clinical StudiesClinical Oral Implants Research · 2026
- Operator experience on robotic and dynamic computer-assisted implant surgery (CAIS): an in vitro controlled study.Journal of dentistry · 2026
- Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients in a private practice: A retrospective cohort study.Journal of dentistry · 2026
- Short implant placement using dynamic and robotic computer-assisted implant surgery (d-CAIS and r-CAIS): a controlled in vitro study.Journal of dentistry · 2026
- Sources of Error in Static Computer-Assisted Implant Surgery: A Critical Review of Error Propagation Through the Digital Workflow.Dentistry journal · 2026